API · ASME · DIN · EN 規格対応の産業用バルブ

エアリリーフバルブ(空気弁)

配管の高所に滞留する空気を排出し、排水時には空気を吸入して真空やサージを防ぐ水理バルブです。

最終更新: 2026-11

ファミリー仕様

Designs Single Orifice, Double Orifice, Double Orifice Kinetic, Combination
Functions Continuous air release at high points, Air admission during draining (vacuum breaking), Rapid air discharge during filling (kinetic)
Nominal valve connection size 1" to 20" (single body 1"-8", dual body 10"-20")
Pressure class / nominal rating designation PN10, PN16, Class 125
Service temperature range -20 to 180°C (KXC single release, water/oil/gas)
Materials (component scope as published) WCB (ASTM A216), CF8, CF8M (ASTM A351), F316, F316L (ASTM A182), F51/2205 duplex (ASTM A182), F53, F55/2507 super duplex (ASTM A182), C95400, C95800 aluminium bronze (ASTM B148), nickel-copper alloy 400, nickel-chromium alloy 625 (ASTM B564)
Float And Trim T316 stainless steel floats, stainless steel 316 internal trim, resilient seating, full pipe size inlets/outlets
Design standards AWWA C512
Certifications NSF 372 Certified Lead-Free, NSF 61 Certified for Drinking Water, Meets AWWA C512
design focus Air discharge and admission capacity, float response speed and stability, tight sealing under system pressure, fouling resistance, structural integrity under surge
awwa c512 types Air Release, Air/Vacuum, Combination
air release sizing rule Dissolved air approx. 2% by volume; venting capacity q = Q (GPM) x 0.13 cu ft/gal x 0.02 (SCFM)
air vacuum sizing differential 2 psi (14 kPa) standard; up to 5 psi (35 kPa) with slow-closing device
vacuum sizing criterion Admit air at the lower of 5 psi differential or pipe collapse pressure
awwa m51 location schedule High points: combination; long horizontal runs, descents, ascents: valves at 1250-2500 ft (380-760 m) intervals; flow meters: air release upstream; well/vertical turbine pumps: air/vacuum with slow-closing or throttling device
anti shock design Anti-shock air valves (e.g. Vent-O-Mat RBX) are designed so air-discharge closure limits the transient pressure rise to 1.5x rated working pressure, controlling slam/surge on fast-filling lines
dynamic floatless design Floatless dynamic combination air valves (A.R.I. D-070) replace floats with a rolling diaphragm and a small pilot orifice: air discharges through the large orifice, then system pressure acting on the pilot lowers the rolling-diaphragm assembly to seal it — a design aimed at resisting fouling in wastewater service
air valve maintenance interval A.R.I. D-070 IOM: the valve should be maintained at least once a year, in accordance with the quality and composition of the fluid in the system; seals and diaphragm inspected for cracks and tears
installation air trap sizing A.R.I. D-070 IOM installation practice: air-trap riser diameter = pipeline diameter up to 300mm, 60% of diameter up to 1500mm, 35% above; riser up to 150mm; air trap at least 150mm; a manual isolation valve is required under the valve inlet
compressed gas hazard Air release valves — especially wastewater models — may contain a significant volume of compressed gas with accumulated energy; depressurize before servicing
working pressure excludes surge Manufacturer IOM note: the stated maximum working pressure does not include pressure changes caused by water hammer and surge effects — surge analysis is a separate duty check
rbx positioning schedule Vent-O-Mat RBX installation schedule: air valves at system summits and high points, along long horizontal runs and at significant grade changes, downstream of pump discharge / after check valves, and at blank ends; single-chamber anti-shock combination design (PN16/25/40, DN25-200)
factory testing Vent-O-Mat RBX factory tests include hydrostatic pressure tests at 1.5x rated pressure, low-pressure sealing checks, and float/mechanism drop testing on a sampled basis

範囲と出所の注記

air valve type taxonomy Vendor catalog tree lists four designs (Single Orifice / Double Orifice / Double Orifice Kinetic / Combination), while AWWA C512-15 standardizes three basic types: Air Release, Air/Vacuum, Combination. 'Double Orifice Kinetic' is vendor vocabulary corresponding to kinetic/air-release designs under the standard taxonomy; reconcile on next taxonomy pass.

注文と書類

書類

お問い合わせの際に必要な書類セットをお知らせください——この型番仕様の典型的な項目(材質証明書、記載の検査規格に基づく試験報告書、寸法図)は、見積時に確認のうえ供給されます。

お見積り

見積可能なお問い合わせには次の事項をご記入ください:呼び径と圧力レーティング、ボディ・シート材質の希望、接続方式、操作方式、温度を含む使用流体。このページの典型値はベンチマーク参考範囲です。拘束力のある値は見積時に確定します。

サンプルと供給

供給条件、発注数量、納期は注文ごとに協議します——お問い合わせの際に納入国と希望スケジュールをお知らせください。

保管と輸送

バルブはシート・シールを紫外線、オゾン、変形から保護して保管し、据付まで端面保護カバーを取り付けたままにしてください。エラストマーまたは PTFE シートの仕様では、屋外での長期保管を避けてください——シート材料は直射日光と凍結条件で最も劣化が早くなります。

よくある質問

エアリリーフバルブ(空気弁)の見積依頼には何を含めるべきですか?

適用規格とクラス、呼びサイズ、ボディおよびシート材、使用媒体と温度、納入先——欠落している項目は見積の過程で確認します。

エアリリーフバルブ(空気弁)にはどのサイズと圧力等級がありますか?

このバルブの検証済みサイズと圧力等級範囲はまだ本ページに掲載されていません——お客様の使用条件に適したサイズと圧力等級は見積の過程でご提案し、確認します。使用条件を問い合わせに添えていただければ、選定結果を見積書に記載します。

エアリリーフバルブ(空気弁)にはどのボディ材質がありますか?

このバルブの検証済みボディ材質範囲はまだ本ページに掲載されていません——お客様の使用条件に適したボディ材質は見積の過程でご提案し、確認します。使用条件を問い合わせに添えていただければ、選定結果を見積書に記載します。

このファミリーのタイプ

タイプ

シングルオリフィス空気弁

シングルオリフィス空気弁は1つの小オリフィスで液体ラインから滞留空気を排出します。チャンバーに空気が溜まるとステンレスフロートが下降してシートを開き空気溜まりを放出し、戻った水で上昇して閉じます。範囲はボディ・バケット・カバー・ボンネットが鋳鉄・ダクタイル鋳鉄・ステンレス鋼、フロート・ステム・ヨーク・プラグはステンレス

仕様を見る →

タイプ

ダブルオリフィス空気弁

ダブルオリフィス空気弁は1つのボディに大口径段と小口径段を組み合わせます。大口径段は配管充填時の大量空気を排出し排水時には空気を吸入、小口径段は加圧下で集まる空気溜まりを放出します。充填時と定常運転の両方で幹線配管を保護する組合せです。範囲はボディ・ボンネット・グランド・上部キャップがダクタイル鋳鉄または鋳鉄、ボールは

仕様を見る →

タイプ

コンビネーションエアリリーフバルブ

コンビネーションエアリリーフバルブは1つの組立品に空気/真空機能と連続排気機能を併せ持ちます。配管立ち上げ時に大量の空気を排出し、運転中の空気溜まりを放出し、排水時には空気を吸入して真空・サージから守る、清浄水幹線の高所用標準弁および下水幹線向けの苛酷用バージョンです。範囲は清浄水用の1"~8"の単体型と10"~20"

仕様を見る →

エアリリーフバルブ(空気弁) の見積依頼

こちらからご要望をご提出ください——見積に直結するお問い合わせには、適用規格とクラス、口径、材質、流体、温度、納入先をご記入ください.

お客様の情報の取り扱いについては、プライバシー通知をご覧ください。

エアリリーフバルブ(空気弁) のお見積りを取得

規格・圧力クラス・口径をお知らせください。見積可能なお問い合わせとして、書類と条件を添えてご返信します。