Válvulas industriales según normas API · ASME · DIN · EN

Válvulas de purga de aire

Válvulas hidráulicas que ventan el aire atrapado en los puntos altos de la tubería y admiten aire durante el drenaje para prevenir vacío y golpe de ariete.

Última actualización: 2026-11

Especificaciones de la familia

Designs Single Orifice, Double Orifice, Double Orifice Kinetic, Combination
Functions Continuous air release at high points, Air admission during draining (vacuum breaking), Rapid air discharge during filling (kinetic)
Nominal valve connection size 1" to 20" (single body 1"-8", dual body 10"-20")
Pressure class / nominal rating designation PN10, PN16, Class 125
Service temperature range -20 to 180°C (KXC single release, water/oil/gas)
Materials (component scope as published) WCB (ASTM A216), CF8, CF8M (ASTM A351), F316, F316L (ASTM A182), F51/2205 duplex (ASTM A182), F53, F55/2507 super duplex (ASTM A182), C95400, C95800 aluminium bronze (ASTM B148), nickel-copper alloy 400, nickel-chromium alloy 625 (ASTM B564)
Float And Trim T316 stainless steel floats, stainless steel 316 internal trim, resilient seating, full pipe size inlets/outlets
Design standards AWWA C512
Certifications NSF 372 Certified Lead-Free, NSF 61 Certified for Drinking Water, Meets AWWA C512
design focus Air discharge and admission capacity, float response speed and stability, tight sealing under system pressure, fouling resistance, structural integrity under surge
awwa c512 types Air Release, Air/Vacuum, Combination
air release sizing rule Dissolved air approx. 2% by volume; venting capacity q = Q (GPM) x 0.13 cu ft/gal x 0.02 (SCFM)
air vacuum sizing differential 2 psi (14 kPa) standard; up to 5 psi (35 kPa) with slow-closing device
vacuum sizing criterion Admit air at the lower of 5 psi differential or pipe collapse pressure
awwa m51 location schedule High points: combination; long horizontal runs, descents, ascents: valves at 1250-2500 ft (380-760 m) intervals; flow meters: air release upstream; well/vertical turbine pumps: air/vacuum with slow-closing or throttling device
anti shock design Anti-shock air valves (e.g. Vent-O-Mat RBX) are designed so air-discharge closure limits the transient pressure rise to 1.5x rated working pressure, controlling slam/surge on fast-filling lines
dynamic floatless design Floatless dynamic combination air valves (A.R.I. D-070) replace floats with a rolling diaphragm and a small pilot orifice: air discharges through the large orifice, then system pressure acting on the pilot lowers the rolling-diaphragm assembly to seal it — a design aimed at resisting fouling in wastewater service
air valve maintenance interval A.R.I. D-070 IOM: the valve should be maintained at least once a year, in accordance with the quality and composition of the fluid in the system; seals and diaphragm inspected for cracks and tears
installation air trap sizing A.R.I. D-070 IOM installation practice: air-trap riser diameter = pipeline diameter up to 300mm, 60% of diameter up to 1500mm, 35% above; riser up to 150mm; air trap at least 150mm; a manual isolation valve is required under the valve inlet
compressed gas hazard Air release valves — especially wastewater models — may contain a significant volume of compressed gas with accumulated energy; depressurize before servicing
working pressure excludes surge Manufacturer IOM note: the stated maximum working pressure does not include pressure changes caused by water hammer and surge effects — surge analysis is a separate duty check
rbx positioning schedule Vent-O-Mat RBX installation schedule: air valves at system summits and high points, along long horizontal runs and at significant grade changes, downstream of pump discharge / after check valves, and at blank ends; single-chamber anti-shock combination design (PN16/25/40, DN25-200)
factory testing Vent-O-Mat RBX factory tests include hydrostatic pressure tests at 1.5x rated pressure, low-pressure sealing checks, and float/mechanism drop testing on a sampled basis

Notas de alcance y fuentes

air valve type taxonomy Vendor catalog tree lists four designs (Single Orifice / Double Orifice / Double Orifice Kinetic / Combination), while AWWA C512-15 standardizes three basic types: Air Release, Air/Vacuum, Combination. 'Double Orifice Kinetic' is vendor vocabulary corresponding to kinetic/air-release designs under the standard taxonomy; reconcile on next taxonomy pass.

Pedido y documentación

Documentos

Solicite con la consulta el conjunto documental que necesite — los elementos habituales para esta ejecución (certificados de material, informes de ensayo según la norma de inspección indicada, planos dimensionales) se confirman y entregan con la cotización.

Cotización

Una consulta lista para cotizar indica: medida nominal y clase de presión, preferencia de materiales del cuerpo y del asiento, conexión terminal, accionamiento, y el fluido de servicio con su temperatura. Los valores típicos de esta página son rangos de referencia; los valores vinculantes se confirman en la cotización.

Muestra y suministro

Las condiciones de suministro, cantidades pedidas y plazos se acuerdan por pedido — indique el país de destino y el calendario requerido con la consulta.

Almacenamiento y envío

Almacene las válvulas con asientos y sellos protegidos de UV, ozono y deformación, mantenga los protectores de cara terminal hasta la instalación y, en ejecuciones con asiento de elastómero o PTFE, evite el almacenamiento prolongado a la intemperie — los compuestos de asiento envejecen más rápido al sol directo y en condiciones de congelación.

Preguntas frecuentes

¿Qué debe incluir una solicitud de cotización para válvulas de purga de aire?

La norma y clase aplicables, el tamaño nominal, los materiales de cuerpo y asiento, el medio de servicio con su temperatura y el destino — lo que falte se confirma durante la cotización.

¿Qué tamaño y clase de presión están disponibles en válvulas de purga de aire?

Un rango verificado de tamaño y clase de presión para esta válvula aún no está publicado en esta página — el tamaño y clase de presión aplicable a su servicio se propone y confirma durante la cotización. Envíe las condiciones de servicio con la solicitud y la selección se indica en la oferta.

¿Qué material del cuerpo están disponibles en válvulas de purga de aire?

Un rango verificado de material del cuerpo para esta válvula aún no está publicado en esta página — el material del cuerpo aplicable a su servicio se propone y confirma durante la cotización. Envíe las condiciones de servicio con la solicitud y la selección se indica en la oferta.

Solicitar presupuesto para Válvulas de purga de aire

Envíe el requerimiento aquí — una consulta lista para cotizar indica la norma y clase aplicables, medida, materiales, fluido, temperatura y destino.

Lo que ocurre con sus datos está descrito en nuestro aviso de privacidad.

Obtener un presupuesto para Válvulas de purga de aire

Envíe la norma, la clase de presión y la medida para una consulta lista para cotizar — respuesta con documentación y condiciones.