API · ASME · DIN · EN standartlı endüstriyel vanalar

Hava Tahliye Vanaları

Boru hattının tepe noktalarında hapsedilen havayı tahliye eden ve vakum ile su darbesini önlemek için boşaltmada hava alan hidrolik vanalar.

Son güncelleme: 2026-11

Aile özellikleri

Designs Single Orifice, Double Orifice, Double Orifice Kinetic, Combination
Functions Continuous air release at high points, Air admission during draining (vacuum breaking), Rapid air discharge during filling (kinetic)
Nominal valve connection size 1" to 20" (single body 1"-8", dual body 10"-20")
Pressure class / nominal rating designation PN10, PN16, Class 125
Service temperature range -20 to 180°C (KXC single release, water/oil/gas)
Materials (component scope as published) WCB (ASTM A216), CF8, CF8M (ASTM A351), F316, F316L (ASTM A182), F51/2205 duplex (ASTM A182), F53, F55/2507 super duplex (ASTM A182), C95400, C95800 aluminium bronze (ASTM B148), nickel-copper alloy 400, nickel-chromium alloy 625 (ASTM B564)
Float And Trim T316 stainless steel floats, stainless steel 316 internal trim, resilient seating, full pipe size inlets/outlets
Design standards AWWA C512
Certifications NSF 372 Certified Lead-Free, NSF 61 Certified for Drinking Water, Meets AWWA C512
design focus Air discharge and admission capacity, float response speed and stability, tight sealing under system pressure, fouling resistance, structural integrity under surge
awwa c512 types Air Release, Air/Vacuum, Combination
air release sizing rule Dissolved air approx. 2% by volume; venting capacity q = Q (GPM) x 0.13 cu ft/gal x 0.02 (SCFM)
air vacuum sizing differential 2 psi (14 kPa) standard; up to 5 psi (35 kPa) with slow-closing device
vacuum sizing criterion Admit air at the lower of 5 psi differential or pipe collapse pressure
awwa m51 location schedule High points: combination; long horizontal runs, descents, ascents: valves at 1250-2500 ft (380-760 m) intervals; flow meters: air release upstream; well/vertical turbine pumps: air/vacuum with slow-closing or throttling device
anti shock design Anti-shock air valves (e.g. Vent-O-Mat RBX) are designed so air-discharge closure limits the transient pressure rise to 1.5x rated working pressure, controlling slam/surge on fast-filling lines
dynamic floatless design Floatless dynamic combination air valves (A.R.I. D-070) replace floats with a rolling diaphragm and a small pilot orifice: air discharges through the large orifice, then system pressure acting on the pilot lowers the rolling-diaphragm assembly to seal it — a design aimed at resisting fouling in wastewater service
air valve maintenance interval A.R.I. D-070 IOM: the valve should be maintained at least once a year, in accordance with the quality and composition of the fluid in the system; seals and diaphragm inspected for cracks and tears
installation air trap sizing A.R.I. D-070 IOM installation practice: air-trap riser diameter = pipeline diameter up to 300mm, 60% of diameter up to 1500mm, 35% above; riser up to 150mm; air trap at least 150mm; a manual isolation valve is required under the valve inlet
compressed gas hazard Air release valves — especially wastewater models — may contain a significant volume of compressed gas with accumulated energy; depressurize before servicing
working pressure excludes surge Manufacturer IOM note: the stated maximum working pressure does not include pressure changes caused by water hammer and surge effects — surge analysis is a separate duty check
rbx positioning schedule Vent-O-Mat RBX installation schedule: air valves at system summits and high points, along long horizontal runs and at significant grade changes, downstream of pump discharge / after check valves, and at blank ends; single-chamber anti-shock combination design (PN16/25/40, DN25-200)
factory testing Vent-O-Mat RBX factory tests include hydrostatic pressure tests at 1.5x rated pressure, low-pressure sealing checks, and float/mechanism drop testing on a sampled basis

Kapsam ve kaynak notları

air valve type taxonomy Vendor catalog tree lists four designs (Single Orifice / Double Orifice / Double Orifice Kinetic / Combination), while AWWA C512-15 standardizes three basic types: Air Release, Air/Vacuum, Combination. 'Double Orifice Kinetic' is vendor vocabulary corresponding to kinetic/air-release designs under the standard taxonomy; reconcile on next taxonomy pass.

Sipariş ve dokümantasyon

Dokümanlar

İhtiyacınız olan dokümantasyon setini talep ile birlikte isteyin — bu icra için tipik kalemler (malzeme sertifikaları, listelenen denetim standardına uygun test raporları, boyut çizimleri) teklifte teyit edilir ve onunla birlikte tedarik edilir.

Teklif

Teklife hazır bir talep şunları belirtir: nominal boyut ve basınç sınıfı, gövde ve yatak malzemesi tercihi, uç bağlantısı, tahrik ve sıcaklıkla birlikte görev ortamı. Bu sayfadaki tipik değerler kıyaslama referans aralıklarıdır; bağlayıcı değerler teklifte teyit edilir.

Numune ve tedarik

Tedarik şartları, sipariş adetleri ve teslim süresi sipariş başına kararlaştırılır — talep ile birlikte varış ülkesini ve gerekli takvimi belirtin.

Depolama ve sevkiyat

Vanaları yatakları ve sızdırmazlık elemanları UV, ozon ve deformasyondan korunacak şekilde depolayın, uç yüzey koruyucularını montaja kadar takılı tutun; elastomer veya PTFE yataklı icralarda uzun süreli açık alanda depolamadan kaçının — yatak bileşikleri doğrudan güneş ışığında ve don koşullarında en hızlı yaşlanır.

Sık sorulan sorular

hava tahliye vanaları için bir teklif sorgusu neyi içermelidir?

Geçerli norm ve sınıf, nominal boyut, gövde ve sedir malzemeleri, sıcaklığıyla servis ortamı ve varış yeri — eksik olan her şey teklif sırasında doğrulanır.

hava tahliye vanaları içinde hangi boyut ve basınç derecesi mevcuttur?

Bu vana için doğrulanmış bir boyut ve basınç derecesi aralığı henüz bu sayfada yayımlanmamıştır — göreviniz için uygun boyut ve basınç derecesi önerilir ve teklif sırasında doğrulanır. Servis koşullarını sorguyla birlikte gönderin; seçim, teklifte belirtilir.

hava tahliye vanaları içinde hangi gövde malzemesi mevcuttur?

Bu vana için doğrulanmış bir gövde malzemesi aralığı henüz bu sayfada yayımlanmamıştır — göreviniz için uygun gövde malzemesi önerilir ve teklif sırasında doğrulanır. Servis koşullarını sorguyla birlikte gönderin; seçim, teklifte belirtilir.

Hava Tahliye Vanaları için teklif isteyin

Gereksiniminizi buradan gönderin — teklife hazır bir talep, yönetici standart ve sınıfı, boyutu, malzemeleri, ortamı, sıcaklığı ve varış ülkesini belirtir.

Bilgilerinize ne olacağı gizlilik bildirimimizde açıklanmıştır.

Hava Tahliye Vanaları için teklif alın

Teklife hazır bir talep için standart, basınç sınıfı ve boyutu gönderin — dokümanlar ve şartlarla yanıtlarız.