패밀리 사양
| Designs | Single Orifice, Double Orifice, Double Orifice Kinetic, Combination |
|---|---|
| Functions | Continuous air release at high points, Air admission during draining (vacuum breaking), Rapid air discharge during filling (kinetic) |
| Nominal valve connection size | 1" to 20" (single body 1"-8", dual body 10"-20") |
| Pressure class / nominal rating designation | PN10, PN16, Class 125 |
| Service temperature range | -20 to 180°C (KXC single release, water/oil/gas) |
| Materials (component scope as published) | WCB (ASTM A216), CF8, CF8M (ASTM A351), F316, F316L (ASTM A182), F51/2205 duplex (ASTM A182), F53, F55/2507 super duplex (ASTM A182), C95400, C95800 aluminium bronze (ASTM B148), nickel-copper alloy 400, nickel-chromium alloy 625 (ASTM B564) |
| Float And Trim | T316 stainless steel floats, stainless steel 316 internal trim, resilient seating, full pipe size inlets/outlets |
| Design standards | AWWA C512 |
| Certifications | NSF 372 Certified Lead-Free, NSF 61 Certified for Drinking Water, Meets AWWA C512 |
| design focus | Air discharge and admission capacity, float response speed and stability, tight sealing under system pressure, fouling resistance, structural integrity under surge |
| awwa c512 types | Air Release, Air/Vacuum, Combination |
| air release sizing rule | Dissolved air approx. 2% by volume; venting capacity q = Q (GPM) x 0.13 cu ft/gal x 0.02 (SCFM) |
| air vacuum sizing differential | 2 psi (14 kPa) standard; up to 5 psi (35 kPa) with slow-closing device |
| vacuum sizing criterion | Admit air at the lower of 5 psi differential or pipe collapse pressure |
| awwa m51 location schedule | High points: combination; long horizontal runs, descents, ascents: valves at 1250-2500 ft (380-760 m) intervals; flow meters: air release upstream; well/vertical turbine pumps: air/vacuum with slow-closing or throttling device |
| anti shock design | Anti-shock air valves (e.g. Vent-O-Mat RBX) are designed so air-discharge closure limits the transient pressure rise to 1.5x rated working pressure, controlling slam/surge on fast-filling lines |
| dynamic floatless design | Floatless dynamic combination air valves (A.R.I. D-070) replace floats with a rolling diaphragm and a small pilot orifice: air discharges through the large orifice, then system pressure acting on the pilot lowers the rolling-diaphragm assembly to seal it — a design aimed at resisting fouling in wastewater service |
| air valve maintenance interval | A.R.I. D-070 IOM: the valve should be maintained at least once a year, in accordance with the quality and composition of the fluid in the system; seals and diaphragm inspected for cracks and tears |
| installation air trap sizing | A.R.I. D-070 IOM installation practice: air-trap riser diameter = pipeline diameter up to 300mm, 60% of diameter up to 1500mm, 35% above; riser up to 150mm; air trap at least 150mm; a manual isolation valve is required under the valve inlet |
| compressed gas hazard | Air release valves — especially wastewater models — may contain a significant volume of compressed gas with accumulated energy; depressurize before servicing |
| working pressure excludes surge | Manufacturer IOM note: the stated maximum working pressure does not include pressure changes caused by water hammer and surge effects — surge analysis is a separate duty check |
| rbx positioning schedule | Vent-O-Mat RBX installation schedule: air valves at system summits and high points, along long horizontal runs and at significant grade changes, downstream of pump discharge / after check valves, and at blank ends; single-chamber anti-shock combination design (PN16/25/40, DN25-200) |
| factory testing | Vent-O-Mat RBX factory tests include hydrostatic pressure tests at 1.5x rated pressure, low-pressure sealing checks, and float/mechanism drop testing on a sampled basis |
범위·출처 비고
| air valve type taxonomy | Vendor catalog tree lists four designs (Single Orifice / Double Orifice / Double Orifice Kinetic / Combination), while AWWA C512-15 standardizes three basic types: Air Release, Air/Vacuum, Combination. 'Double Orifice Kinetic' is vendor vocabulary corresponding to kinetic/air-release designs under the standard taxonomy; reconcile on next taxonomy pass. |
|---|
주문·서류
서류
문의 시 필요한 서류 세트를 요청해 주십시오 — 이 구조의 일반적인 항목(재질증명서, 명시된 검사 표준에 따른 시험 성적서, 치수 도면)은 견적 시 확인되어 함께 공급됩니다.
견적
견적에 바로 쓸 수 있는 문의에는 다음을 명시합니다: 공칭 구경과 압력 정격, 바디·시트 재질 선호, 접속 방식, 조작 방식, 온도를 포함한 사용 유체. 이 페이지의 전형값은 벤치마크 참조 범위입니다; 구속력 있는 값은 견적 시 확정됩니다.
샘플·공급
공급 조건, 발주 수량, 납기는 주문별로 합의합니다 — 문의 시 납품 국가와 필요한 일정을 알려 주십시오.
보관·운송
밸브는 시트와 씰을 자외선, 오존, 변형으로부터 보호하여 보관하고, 설치까지 단면 보호캡을 유지하십시오; 탄성체 또는 PTFE 시트 구조는 장기 야외 보관을 피하십시오 — 시트 재료는 직사광선과 동결 조건에서 가장 빨리 노화됩니다.
자주 묻는 질문
에어 릴리스 밸브 견적 문의에는 무엇을 포함해야 하나요?
적용 표준과 등급, 공칭 구경, 바디 및 시트 재질, 온도를 포함한 서비스 유체, 그리고 납품지를 알려 주십시오 — 누락된 항목은 견적 진행 중 확인됩니다.
에어 릴리스 밸브에서 어떤 구경 및 압력 등급을(를) 이용할 수 있나요?
이 밸브에 대해 검증된 구경 및 압력 등급 범위는 아직 이 페이지에 공개되어 있지 않습니다 — 사용 조건에 맞는 구경 및 압력 등급은 견적 과정에서 제안 및 확인됩니다. 문의 시 서비스 조건을 함께 보내 주시면 견적서에 선정 결과를 명시해 드립니다.
에어 릴리스 밸브에서 어떤 바디 재질을(를) 이용할 수 있나요?
이 밸브에 대해 검증된 바디 재질 범위는 아직 이 페이지에 공개되어 있지 않습니다 — 사용 조건에 맞는 바디 재질은 견적 과정에서 제안 및 확인됩니다. 문의 시 서비스 조건을 함께 보내 주시면 견적서에 선정 결과를 명시해 드립니다.
이 패밀리의 타입
타입
싱글 오리피스 에어 밸브
싱글 오리피스 에어 밸브는 하나의 작은 오리피스로 액체 라인의 축적 공기를 배출합니다: 챔버에 공기가 모이면 스테인리스 플로트가 내려가 시트를 열어 공기 주머니를 방출하고, 유체가 돌아오면 다시 올라가 닫습니다. 범위는 주철, 구상주철 또는 스테인리스 바디·버킷·커버·보닛에 스테인리스
사양 보기 →타입
더블 오리피스 에어 밸브
더블 오리피스 에어 밸브는 하나의 바디에 대구경 스테이지와 소구경 스테이지를 짝짓습니다: 대구경 스테이지는 충전 시 대량 공기를 방출하고 배수 시 공기를 유입하며, 소구경 스테이지는 압력 하에서 모이는 공기 주머니를 블리드합니다 — 충전 시와 정상 상태 양쪽에서 수송 계통을 보호하는 조
사양 보기 →타입
컴비네이션 에어 릴리스 밸브
컴비네이션 에어 릴리스 밸브는 하나의 조립체에서 공기/진공 기능과 연속 에어 릴리스 기능을 짝짓습니다: 파이프라인 기동 시 대량 공기를 배출하고, 운전 중 축적 공기 주머니를 방출하며, 배수 시 공기를 유입해 진공 및 서지로부터 보호합니다 — 깨끗한 물 수송의 표준 고점 밸브이며, 하수
사양 보기 →에어 릴리스 밸브 견적 요청
여기서 요구사항을 제출하십시오 — 견적에 바로 쓸 수 있는 문의에는 적용 표준과 등급, 구경, 재질, 유체, 온도, 납품지가 담겨 있습니다.