Vannes industrielles aux normes API · ASME · DIN · EN

Purgeurs d'air

Vannes hydrauliques purgant l'air piégé aux points hauts du réseau et admettant de l'air lors de la vidange pour prévenir vide et coup de bélier.

Dernière mise à jour : 2026-11

Caractéristiques de la famille

Designs Single Orifice, Double Orifice, Double Orifice Kinetic, Combination
Functions Continuous air release at high points, Air admission during draining (vacuum breaking), Rapid air discharge during filling (kinetic)
Nominal valve connection size 1" to 20" (single body 1"-8", dual body 10"-20")
Pressure class / nominal rating designation PN10, PN16, Class 125
Service temperature range -20 to 180°C (KXC single release, water/oil/gas)
Materials (component scope as published) WCB (ASTM A216), CF8, CF8M (ASTM A351), F316, F316L (ASTM A182), F51/2205 duplex (ASTM A182), F53, F55/2507 super duplex (ASTM A182), C95400, C95800 aluminium bronze (ASTM B148), nickel-copper alloy 400, nickel-chromium alloy 625 (ASTM B564)
Float And Trim T316 stainless steel floats, stainless steel 316 internal trim, resilient seating, full pipe size inlets/outlets
Design standards AWWA C512
Certifications NSF 372 Certified Lead-Free, NSF 61 Certified for Drinking Water, Meets AWWA C512
design focus Air discharge and admission capacity, float response speed and stability, tight sealing under system pressure, fouling resistance, structural integrity under surge
awwa c512 types Air Release, Air/Vacuum, Combination
air release sizing rule Dissolved air approx. 2% by volume; venting capacity q = Q (GPM) x 0.13 cu ft/gal x 0.02 (SCFM)
air vacuum sizing differential 2 psi (14 kPa) standard; up to 5 psi (35 kPa) with slow-closing device
vacuum sizing criterion Admit air at the lower of 5 psi differential or pipe collapse pressure
awwa m51 location schedule High points: combination; long horizontal runs, descents, ascents: valves at 1250-2500 ft (380-760 m) intervals; flow meters: air release upstream; well/vertical turbine pumps: air/vacuum with slow-closing or throttling device
anti shock design Anti-shock air valves (e.g. Vent-O-Mat RBX) are designed so air-discharge closure limits the transient pressure rise to 1.5x rated working pressure, controlling slam/surge on fast-filling lines
dynamic floatless design Floatless dynamic combination air valves (A.R.I. D-070) replace floats with a rolling diaphragm and a small pilot orifice: air discharges through the large orifice, then system pressure acting on the pilot lowers the rolling-diaphragm assembly to seal it — a design aimed at resisting fouling in wastewater service
air valve maintenance interval A.R.I. D-070 IOM: the valve should be maintained at least once a year, in accordance with the quality and composition of the fluid in the system; seals and diaphragm inspected for cracks and tears
installation air trap sizing A.R.I. D-070 IOM installation practice: air-trap riser diameter = pipeline diameter up to 300mm, 60% of diameter up to 1500mm, 35% above; riser up to 150mm; air trap at least 150mm; a manual isolation valve is required under the valve inlet
compressed gas hazard Air release valves — especially wastewater models — may contain a significant volume of compressed gas with accumulated energy; depressurize before servicing
working pressure excludes surge Manufacturer IOM note: the stated maximum working pressure does not include pressure changes caused by water hammer and surge effects — surge analysis is a separate duty check
rbx positioning schedule Vent-O-Mat RBX installation schedule: air valves at system summits and high points, along long horizontal runs and at significant grade changes, downstream of pump discharge / after check valves, and at blank ends; single-chamber anti-shock combination design (PN16/25/40, DN25-200)
factory testing Vent-O-Mat RBX factory tests include hydrostatic pressure tests at 1.5x rated pressure, low-pressure sealing checks, and float/mechanism drop testing on a sampled basis

Périmètre et notes de sources

air valve type taxonomy Vendor catalog tree lists four designs (Single Orifice / Double Orifice / Double Orifice Kinetic / Combination), while AWWA C512-15 standardizes three basic types: Air Release, Air/Vacuum, Combination. 'Double Orifice Kinetic' is vendor vocabulary corresponding to kinetic/air-release designs under the standard taxonomy; reconcile on next taxonomy pass.

Commande et documentation

Documents

Demandez le jeu de documentation nécessaire avec la demande — les postes types pour cette exécution (certificats matière, rapports d'essai selon la norme d'inspection indiquée, plans dimensionnels) sont confirmés et fournis avec le devis.

Devis

Une demande prête pour le devis énonce : dimension nominale et classe de pression, préférence de matériaux du corps et du siège, raccordement, commande, et le fluide avec sa température. Les valeurs typiques de cette page sont des plages de référence ; les valeurs contractuelles sont confirmées au moment du devis.

Échantillon et fourniture

Les conditions de fourniture, quantités commandées et délais sont convenus par commande — indiquez le pays de destination et le calendrier requis avec la demande.

Stockage et expédition

Stocker les vannes avec sièges et joints protégés des UV, de l'ozone et de la déformation, conserver les protections de faces d'accouplement jusqu'au montage, et pour les exécutions à siège élastomère ou PTFE éviter le stockage extérieur prolongé — les composés de siège vieillissent plus vite en plein soleil et au gel.

Questions fréquentes

Que doit inclure une demande de devis pour purgeurs d'air ?

La norme et la classe de référence, la taille nominale, les matériaux de corps et de siège, le fluide de service avec sa température, et la destination — tout élément manquant est confirmé pendant le devis.

Quels taille et classe de pression sont disponibles sur purgeurs d'air ?

Une plage de taille et classe de pression vérifiée pour cette vanne n'est pas encore publiée sur cette page — le taille et classe de pression applicable à votre fonction est proposé et confirmé pendant le devis. Envoyez les conditions de service avec la demande et la sélection sera énoncée dans l'offre.

Quels matériau de corps sont disponibles sur purgeurs d'air ?

Une plage de matériau de corps vérifiée pour cette vanne n'est pas encore publiée sur cette page — le matériau de corps applicable à votre fonction est proposé et confirmé pendant le devis. Envoyez les conditions de service avec la demande et la sélection sera énoncée dans l'offre.

Demander un devis pour Purgeurs d'air

Soumettez le besoin ici — une demande prête pour le devis énonce la norme et la classe de référence, la dimension, les matériaux, le fluide, la température et la destination.

Le traitement de vos données est décrit dans notre déclaration de confidentialité.

Obtenir un devis pour Purgeurs d'air

Envoyez la norme, la classe de pression et la dimension pour une demande prête pour le devis — réponse avec documents et conditions.