Industriële ventielen volgens API · ASME · DIN · EN
Luchtafvoerkleppen
Hydraulische kleppen die ingesloten lucht bij pijpleiding-hoogtepunten ventileren en lucht toelaten tijdens het aftappen om vacuüm en surge te voorkomen.
Laatst bijgewerkt: 2026-11
Familiespecificaties
| Designs | Single Orifice, Double Orifice, Double Orifice Kinetic, Combination |
|---|---|
| Functions | Continuous air release at high points, Air admission during draining (vacuum breaking), Rapid air discharge during filling (kinetic) |
| Nominal valve connection size | 1" to 20" (single body 1"-8", dual body 10"-20") |
| Pressure class / nominal rating designation | PN10, PN16, Class 125 |
| Service temperature range | -20 to 180°C (KXC single release, water/oil/gas) |
| Materials (component scope as published) | WCB (ASTM A216), CF8, CF8M (ASTM A351), F316, F316L (ASTM A182), F51/2205 duplex (ASTM A182), F53, F55/2507 super duplex (ASTM A182), C95400, C95800 aluminium bronze (ASTM B148), nickel-copper alloy 400, nickel-chromium alloy 625 (ASTM B564) |
| Float And Trim | T316 stainless steel floats, stainless steel 316 internal trim, resilient seating, full pipe size inlets/outlets |
| Design standards | AWWA C512 |
| Certifications | NSF 372 Certified Lead-Free, NSF 61 Certified for Drinking Water, Meets AWWA C512 |
| design focus | Air discharge and admission capacity, float response speed and stability, tight sealing under system pressure, fouling resistance, structural integrity under surge |
| awwa c512 types | Air Release, Air/Vacuum, Combination |
| air release sizing rule | Dissolved air approx. 2% by volume; venting capacity q = Q (GPM) x 0.13 cu ft/gal x 0.02 (SCFM) |
| air vacuum sizing differential | 2 psi (14 kPa) standard; up to 5 psi (35 kPa) with slow-closing device |
| vacuum sizing criterion | Admit air at the lower of 5 psi differential or pipe collapse pressure |
| awwa m51 location schedule | High points: combination; long horizontal runs, descents, ascents: valves at 1250-2500 ft (380-760 m) intervals; flow meters: air release upstream; well/vertical turbine pumps: air/vacuum with slow-closing or throttling device |
| anti shock design | Anti-shock air valves (e.g. Vent-O-Mat RBX) are designed so air-discharge closure limits the transient pressure rise to 1.5x rated working pressure, controlling slam/surge on fast-filling lines |
| dynamic floatless design | Floatless dynamic combination air valves (A.R.I. D-070) replace floats with a rolling diaphragm and a small pilot orifice: air discharges through the large orifice, then system pressure acting on the pilot lowers the rolling-diaphragm assembly to seal it — a design aimed at resisting fouling in wastewater service |
| air valve maintenance interval | A.R.I. D-070 IOM: the valve should be maintained at least once a year, in accordance with the quality and composition of the fluid in the system; seals and diaphragm inspected for cracks and tears |
| installation air trap sizing | A.R.I. D-070 IOM installation practice: air-trap riser diameter = pipeline diameter up to 300mm, 60% of diameter up to 1500mm, 35% above; riser up to 150mm; air trap at least 150mm; a manual isolation valve is required under the valve inlet |
| compressed gas hazard | Air release valves — especially wastewater models — may contain a significant volume of compressed gas with accumulated energy; depressurize before servicing |
| working pressure excludes surge | Manufacturer IOM note: the stated maximum working pressure does not include pressure changes caused by water hammer and surge effects — surge analysis is a separate duty check |
| rbx positioning schedule | Vent-O-Mat RBX installation schedule: air valves at system summits and high points, along long horizontal runs and at significant grade changes, downstream of pump discharge / after check valves, and at blank ends; single-chamber anti-shock combination design (PN16/25/40, DN25-200) |
| factory testing | Vent-O-Mat RBX factory tests include hydrostatic pressure tests at 1.5x rated pressure, low-pressure sealing checks, and float/mechanism drop testing on a sampled basis |
Omvang & bronnotities
| air valve type taxonomy | Vendor catalog tree lists four designs (Single Orifice / Double Orifice / Double Orifice Kinetic / Combination), while AWWA C512-15 standardizes three basic types: Air Release, Air/Vacuum, Combination. 'Double Orifice Kinetic' is vendor vocabulary corresponding to kinetic/air-release designs under the standard taxonomy; reconcile on next taxonomy pass. |
|---|
Bestelling & documentatie
Documenten
Vraag de benodigde documentatieset mee aan bij de aanvraag — gebruikelijke items voor deze uitvoering (materiaalcertificaten, testrapporten volgens de genoemde inspectienorm, maattekeningen) worden in de offerte bevestigd en meegestuurd.
Offerte
Een offerteklare aanvraag noemt: nominale maat en drukklasse, voorkeur voor huis- en zittingsmateriaal, aansluiting, bediening, en het medium met temperatuur. Typische waarden op deze pagina zijn benchmarkreferentiebereiken; de bindende waarden worden in de offerte bevestigd.
Sample & levering
Leveringsvoorwaarden, orderhoeveelheden en levertijd worden per order afgesproken — noem het bestemmingsland en het gewenste schema bij de aanvraag.
Opslag & verzending
Bewaar ventielen met zittingen en afdichtingen beschermd tegen UV, ozon en vervorming, houd de vlakbeschermers op de aansluitvlakken tot installatie, en vermijd bij uitvoeringen met elastomeer- of PTFE-zittingen langdurige buitenopslag — zittingscompounden verouderen het snelst in direct zonlicht en bij vorst.
Veelgestelde vragen
Wat moet een offerteaanvraag voor luchtafvoerkleppen bevatten?
De geldende norm en klasse, de nominale maat, de body- en zittingmaterialen, het medium met temperatuur en de bestemming — ontbrekende informatie wordt tijdens de offerte bevestigd.
Welke maat en drukklasse zijn er beschikbaar bij luchtafvoerkleppen?
Een geverifieerd maat en drukklasse-bereik voor deze klep is nog niet op deze pagina gepubliceerd — het maat en drukklasse dat voor uw toepassing geldt, wordt voorgesteld en bevestigd tijdens de offerte. Stuur de bedrijfsomstandigheden mee met de aanvraag; de selectie wordt in het aanbod vermeld.
Welke bodymateriaal zijn er beschikbaar bij luchtafvoerkleppen?
Een geverifieerd bodymateriaal-bereik voor deze klep is nog niet op deze pagina gepubliceerd — het bodymateriaal dat voor uw toepassing geldt, wordt voorgesteld en bevestigd tijdens de offerte. Stuur de bedrijfsomstandigheden mee met de aanvraag; de selectie wordt in het aanbod vermeld.
Types binnen deze familie
Type
Enkel-Orifice Luchtafvoerkleppen
Enkel-orifice luchtafvoerkleppen ventileren verzamelde lucht uit vloeistoflijnen door één klein orifice: een roestvrijstalen vlotter daalt als lucht zich in de
Specificaties bekijken →Type
Dubbel-Orifice Luchtafvoerkleppen
Dubbel-orifice luchtafvoerkleppen paren een groot-orifice-stadium met een klein-orifice-stadium in één lichaam: het grote stadium loost bulklucht terwijl pijple
Specificaties bekijken →Type
Combinatie Luchtafvoerkleppen
Combinatie luchtafvoerkleppen paren een lucht/vacuum-functie met een continue luchtafvoerfunctie in één eenheid: ze voeren grote luchtvolumes af bij pijpleiding
Specificaties bekijken →Offerte aanvragen voor Luchtafvoerkleppen
Dien uw eis hier in — een offerteklare aanvraag noemt de geldende norm en klasse, maat, materialen, medium, temperatuur en bestemming.
Wat er met uw gegevens gebeurt, staat beschreven in onze privacyverklaring.
Offerte voor Luchtafvoerkleppen
Stuur norm, drukklasse en maat voor een offerteklare aanvraag — beantwoord met documenten en voorwaarden.