API · ASME · DIN · EN 標準工業閥門
平衡-流量測量裝置
流量測量裝置與平衡閥配對,在專用接頭處讀取迴路流量——當調節閥自身無固定孔口時作為獨立測點,或空間緊張時作為測量與調節合一閥。產品範圍涵蓋 DZR 銅合金 PN25 系列 DN15 至 DN50(含僅 DN15 的超小流量變體)、不鏽鋼 PN25 系列 DN20 至 DN600,以及 DN50 至 DN400、PN16 的測量調節合一閥,錐形螺紋端依 BS EN 10226-2(ISO 7-1)。測量採直角入口孔板並帶取壓口,供 P84 插入式測試點使用,精度 ±5%:流量依 Q = Kvs × √ΔP / 36 跨固定孔口計算,於兩個測試點讀取。D901 適合按 100 至 400 Pa/m 管摩擦損失設計的系統,僅 DN15 的 D902 測量 0.015 至 0.06 L/s 的超小流量(如風機盤管迴路);D901/D902 資料引用 6.1 Kv 與 4.7 Kvs,螺紋端額定 -10 至 +100 °C / 25 bar(120 °C 時降額至 21.8 bar),依 BS 7350 獲 WRAS 批准至 99 °C。DM950 在一段短管上將雙調節蝶閥與固定孔口測量裝置組合——經典調試套組。為何要平衡:在未平衡的管網中,過多的水流經阻力最小的迴路(通常最靠近泵),阻力大的迴路則水量不足,平衡裝置可適應變流量系統中的壓力變化。
屬於 平衡閥 系列
最後更新: 2026-10
系列規格
| Nominal valve connection size | DN15-DN50 (D901/D902), DN20-DN600 (DM900), DN50-DN400 (DM950G) |
|---|---|
| Pressure class / nominal rating designation | PN25, PN16 |
| Valve body material | DZR Copper Alloy, Stainless Steel |
| dzr line | D901 DN15 to DN50 Flow Measurement Device (FMD) – DZR Copper Alloy PN25 |
| ultra low flow variant | D902 DN15 Only Ultra Low Flow Measurement Device (FMD) – DZR Copper Alloy PN25 |
| stainless line | DM900 DN20 to DN600 Flow Measurement Device (FMD) – Stainless Steel PN25 |
| combined regulating valve | DM950G DN50 to DN400 Flow Measurement and Regulating Valve PN16 |
| threaded connections | D901 - Sizes 1/2" to 2" |
| measuring element | Square-edged entrance orifice plates with tappings for P84 insertion-style test points |
| measurement accuracy | ±5% flow measurement accuracy |
| d901 sizing basis | Suitable for systems with pipe frictional losses of 100 to 400 Pa/m |
| d902 ultra low flow band | 0.015 to 0.06 L/sec (DN15 only; e.g. fan coil units) |
| flow capacity d901 d902 | 6.1 Kv / 4.7 Kvs (literature value) |
| temperature pressure rating | Threaded ends -10 to +100 °C at 25 bar, derated to 23.4 bar at 110 °C and 21.8 bar at 120 °C; compression ends 16 bar at -10 to +30 °C; WRAS approval to 99 °C |
| design standards extra | BS 7350: 1990, BS EN 10226, BS EN 1254-2, BS EN 12165, BS EN 12164 |
| approvals | Water Regulations Advisory Scheme (WRAS) |
| dm950g construction | Double-regulating butterfly valve close-coupled to a fixed-orifice flow measurement device via a spool-piece connector; incorporates P84 pressure test valves |
| kv measurement principle | Q = Kvs × √ΔP / 36 (flow in L/s, ΔP in kPa) across the fixed orifice, read at the two test points |
| commissioning set definition | A regulating valve combined with a separate fixed orifice is commonly called a commissioning set; UK practice is proportional balancing of terminal circuits |
| Source 1 — venturi meter construction | Balancing valve for hydraulic systems. Flow meter with Venturi device. Stainless steel obturator. Complete with quick-fit pressure test ports. |
| Source 2 — flow meter principle | Balancing valve with flow meter and direct reading of flow rate. Ball valve for flow rate adjustment. Graduated scale flow meter with magnetic movement flow rate indicator. |
| Source 2 — flow regulation range | 132402 G 1/2" (ISO 228-1) F 2–7 l/min |
| Source 2 — material rating | Technical data Material : brass Maximum percentage of glycol : 50 % Medium : water, glycol solutions Medium temperature range : -10–110 °C Maximum working pressure : 10 bar |
| Source 3 — flowmeter bypass design | This particular series of valves is equipped with a flow meter for a direct reading of the regulated flow rate. The flow meter is housed in a by-pass circuit on the valve body and can be shut off during normal functioning, allowing fast and easy balancing of circuits without the need for differential pressure gauges. |
| Source 3 — flanged size range | 132 series Balancing valve with flow meter, flanged version sizes DN 65, DN 80 and DN 100 |
| Source 3 — performance rating | Medium temperature range : -10–110 °C Maximum working pressure : 10 bar |
| Source 4 — venturi kvs signal | The venturi is able to accelerate the fluid velocity generating a measureable pressure loss or signal from which a flow co-efficient factor Kvs can be calculated. |
| Source 4 — flow chart reading | From this co-efficient the flow rate passing the valve can be calculated or using the signal the flow rate can be read off the appropriate flow chart |
| Source 5 — venturi in body | On 130 series threaded valves, the flow rate is measured with a Venturi device, housed inside the valve body. This devices guarantees balancing accuracy and is extremely practical to use during setting. |
| Source 5 — straight pipe requirement | We recommend keeping the upstream and downstream sections of pipe straight, as shown in the illustrations below, to ensure accurate flow measurement |
| Source 5 — installation clearance | The balancing valves must be installed in such a way as to ensure free access to the pressure test ports, drain cocks and the adjustment knob. The valves can be fitted on either horizontal or vertical pipes. |
| Source 6 — venturi valve role | Venturi valves provide balance, ease of commissioning, and shut-off in a wide range of HVAC systems. |
| dzr metering venturi accuracy | Integral venturi orifice for greater accuracy +/- 3%, The venturi orifice design allows for more stable signals without adding system resistance |
| dzr metering flow range | Flow range between 0.008 l/s and 3.2 l/s |
| dzr metering connections | FBSP (M/F ISO 7-1, F side ISO 228-1) for use with threaded pipe |
| dzr metering pressure temp rating | Maximum working pressure: 25 bar, Working range: 25 bar / -10oC to 110oC 20 bar / 110oC to 130oC |
| dzr metering size line | Xtra Low Flow DN15, Ultra Low Flow DN15, Low Flow DN15, Standard Flow DN15, Standard Flow DN20, Standard Flow DN25, Standard Flow DN32, Standard Flow DN40, Standard Flow DN50 |
| dzr metering straight pipe rule | installed on straight pipe of the same nominal size as the valve and of minimum length equal to 5 pipe diameters at the inlet (10 diameters when installed at the outlet of a pump) and 2 pipe diameters at the outlet |
| dzr metering applications | Heating Chilled water Domestic hot and cold water, Not suitable for gas |
| dzr metering fluid scope | Not suitable for steam, oil or aggressive fluids |
| dzr metering approvals | WRAS Approved, Exempt from CE marking |
| dzr metering body materials | Body: DZR brass, Test Points: DZR brass |
| dzr metering nickel leaching control | Self-colour DZR brass body to limit nickel leaching and minimise water contamination |
訂購與文件
文件
請在詢問時一併說明您需要的文件組合——此結構的常見項目(材質證明、按所列檢驗標準的測試報告、尺寸圖)將於報價時確認並隨附供應。
報價
可直接報價的詢問應說明:公稱口徑與壓力額定、閥體與閥座材質偏好、端部連接、操作方式,以及含溫度的使用介質。本頁的典型值為基準參考範圍;具有約束力的數值於報價時確認。
樣品與供應
供應條件、訂購數量與交期按訂單議定——請在詢問時說明目的地國家與所需時程。
儲存與運輸
閥門儲存時應保護閥座與密封件免受紫外線、臭氧與變形影響,安裝前保留端面保護蓋;彈性體或 PTFE 閥座結構應避免長期戶外存放——閥座材料在陽光直射與冰凍條件下老化最快。
常見問題
平衡-流量測量裝置的報價詢問應包含哪些內容?
執行標準與壓力等級、公稱口徑、閥體與閥座材質、介質及溫度、目的地——缺失的資訊會在報價過程中確認。
平衡-流量測量裝置提供哪些口徑與壓力等級?
本頁面尚未公布該閥門經驗證的口徑與壓力等級範圍——適用於您工況的口徑與壓力等級會在報價過程中提出並確認。請在詢問時附上工況條件,選型結果會在報價中說明。
平衡-流量測量裝置提供哪些閥體材質?
本頁面尚未公布該閥門經驗證的閥體材質範圍——適用於您工況的閥體材質會在報價過程中提出並確認。請在詢問時附上工況條件,選型結果會在報價中說明。