Industriële ventielen volgens API · ASME · DIN · EN
Filters
In-line filtratie-inrichtingen die pompen, kranen en instrumenten tegen vaste verontreiniging beschermen.
Laatst bijgewerkt: 2026-11
Familiespecificaties
| Designs | Y-Type, Simplex Basket, Duplex Basket |
|---|---|
| Nominal valve connection size | DN25 to DN500 |
| Pressure class / nominal rating designation | ANSI Class 150 to Class 300 |
| Materials (component scope as published) | WCB (ASTM A216), LCB, LCC (ASTM A352), F11, F22 (ASTM A182), CF8, CF8M (ASTM A351), F316, F316L (ASTM A182), F51/2205 duplex (ASTM A182), F53, F55/2507 super duplex (ASTM A182), C95400, C95800 aluminium bronze (ASTM B148), nickel-chromium alloy 625, nickel-copper alloy 400, nickel-molybdenum alloy C276 (ASTM B564) |
| Service temperature range | 0 to 200°C (ductile iron Y-type strainer, water/steam/gas media) |
| Particle retention range | The common strainer particle-retention range runs from 1 inch down to 40 micron (0.0016 inch), set by the choice of perforated metal, mesh or wedge-wire straining element. |
| Operation Modes | Continuous flow during element cleaning (duplex basket), Shutdown required for cleaning (Y-type, simplex basket) |
| Basket Construction | The basket or screen is the heart of the strainer; baskets are offered in stainless steel, nickel-copper alloy or brass across a wide range of perforations and mesh, removing solids from 1/2 inch and larger down to 40 microns. |
| Inspection and pressure-test standards | API 598 |
| design focus | Structural strength under line pressure, open area and flow distribution, differential pressure behaviour, ease of maintenance and element replacement |
| document basis | Selection, installation and maintenance guidance follows the FCI Engineering Specification for the Selection, Installation and Maintenance of Pipeline Strainers (Fluid Controls Institute, Pipeline Strainer Section, 2021). |
| vertical installation | On vertical piping a Y strainer must be installed with its screen pointing downward so sediment is trapped in the debris collection chamber; install the strainer with the debris chamber at the lowest possible position. |
| duplex purpose | Duplex/twin basket strainers exist for lines that cannot be shut down for basket cleanout: flow switches to the second basket while the first is removed, cleaned and replaced. |
| maintenance practice | Schedule cleaning from the established clogging rate: pressure gauges on each side of the strainer show when cleaning is required, and differential pressure switches can drive warning lights or alarms. |
| Source 1 — npt pressure temperature ratings | 250 PSIG @ 406°F - Steam, 400 PSIG @ 150°F - WOG |
| Source 1 — flanged pressure temperature ratings | 125# FLG 125 PSIG @ 450°F - Steam, 125# FLG 200 PSIG @ 150°F - WOG, 250# FLG 250 PSIG @ 450°F - Steam, 250# FLG 500 PSIG @ 150°F - WOG |
| Source 1 — screen seat fit | Machined seat assures perfect fit for screen |
| Source 1 — screen maintenance features | Blowdown connection and easily removable stainless steel cylindrical screens for easy maintenance |
| Source 1 — body construction | Durable cast iron body |
| Source 1 — wog rating definition | WOG = Water, Oil or Gas |
| Source 1 — installation orientation | installed in the flow direction as indicated on the body in either a vertical down or horizontal pipeline |
| Source 1 — maintenance access | The strainer must be accessible for periodic cleaning. |
| Source 2 — body construction | Flanged cast iron strainer |
| Source 2 — port design | Pre-drilled ports |
| Source 2 — service media | works for steam, air, water, oil and gas lines |
| Source 2 — system fit | Ideal for lower capacity piping systems |
| Source 2 — cover cleaning design | blow-off bottom cover for easy cleaning without removing the screen |
| Source 2 — screen design | self-aligning cylindrical screens |
| Source 2 — standard screen material | Stainless steel screen is standard |
| Source 2 — material screen options | body castings and strainer screens are available in a variety of materials, perforations and mesh linings |
| Source 2 — steam rating | Use for steam applications up to 125 psi at 350°F. |
| Source 2 — wog rating | Use for water, oil and gas applications up to 175 psi at 150°F. |
| Source 3 — applicable fluids | Steam, Air, Water |
| Source 3 — Valve body material | Stainless Steel, Cast Iron, Ductile Cast Iron |
| Source 3 — connection types | Screwed, Flanged |
| Source 3 — y3 model envelope | Y3 Stainless Steel Screwed 15 - 50 2.1 220 60 |
| Source 3 — yf model envelope | YF Cast Iron Flanged 15 - 350 0.98 200 40 |
| Source 3 — ydf model envelope | YDF Ductile Cast Iron Flanged 15 - 250 0.98** 40 |
| Source 3 — double layer screen | Double-layer stainless steel screen with large surface area ensures trouble-free operation |
| Source 3 — inline cleaning design | Designed for easy inline cleaning and maintenance |
| Source 3 — y3 all stainless design | Model Y3 made entirely of stainless steel |
Bestelling & documentatie
Documenten
Vraag de benodigde documentatieset mee aan bij de aanvraag — gebruikelijke items voor deze uitvoering (materiaalcertificaten, testrapporten volgens de genoemde inspectienorm, maattekeningen) worden in de offerte bevestigd en meegestuurd.
Offerte
Een offerteklare aanvraag noemt: nominale maat en drukklasse, voorkeur voor huis- en zittingsmateriaal, aansluiting, bediening, en het medium met temperatuur. Typische waarden op deze pagina zijn benchmarkreferentiebereiken; de bindende waarden worden in de offerte bevestigd.
Sample & levering
Leveringsvoorwaarden, orderhoeveelheden en levertijd worden per order afgesproken — noem het bestemmingsland en het gewenste schema bij de aanvraag.
Opslag & verzending
Bewaar ventielen met zittingen en afdichtingen beschermd tegen UV, ozon en vervorming, houd de vlakbeschermers op de aansluitvlakken tot installatie, en vermijd bij uitvoeringen met elastomeer- of PTFE-zittingen langdurige buitenopslag — zittingscompounden verouderen het snelst in direct zonlicht en bij vorst.
Veelgestelde vragen
Wat moet een offerteaanvraag voor filters bevatten?
De geldende norm en klasse, de nominale maat, de body- en zittingmaterialen, het medium met temperatuur en de bestemming — ontbrekende informatie wordt tijdens de offerte bevestigd.
Welke maat en drukklasse zijn er beschikbaar bij filters?
Een geverifieerd maat en drukklasse-bereik voor deze klep is nog niet op deze pagina gepubliceerd — het maat en drukklasse dat voor uw toepassing geldt, wordt voorgesteld en bevestigd tijdens de offerte. Stuur de bedrijfsomstandigheden mee met de aanvraag; de selectie wordt in het aanbod vermeld.
Welke bodymateriaal zijn er beschikbaar bij filters?
Een geverifieerd bodymateriaal-bereik voor deze klep is nog niet op deze pagina gepubliceerd — het bodymateriaal dat voor uw toepassing geldt, wordt voorgesteld en bevestigd tijdens de offerte. Stuur de bedrijfsomstandigheden mee met de aanvraag; de selectie wordt in het aanbod vermeld.
Types binnen deze familie
Type
Y-Filters
Y-filters worden in lijn geplaatst als een terugslagklep, hun schuine arm houdt een geperforeerd of gaas zeef vast die lasteinden, kalk, zand en ander afval vóó
Specificaties bekijken →Type
Simplex Mand-Filters
Simplex mand-filters huisvesten één verwijderbare mand in een verticaal-kamer lichaam: stroming gaat de mand in, afval blijft achter, en schone vloeistof verlaa
Specificaties bekijken →Type
Duplex Mand-Filters
Duplex mand-filters plaatsen twee zeefkamers en een omschakelklep in één eenheid, zodat één mand blijft werken terwijl de andere wordt omgeschakeld en gereinigd
Specificaties bekijken →Offerte aanvragen voor Filters
Dien uw eis hier in — een offerteklare aanvraag noemt de geldende norm en klasse, maat, materialen, medium, temperatuur en bestemming.
Wat er met uw gegevens gebeurt, staat beschreven in onze privacyverklaring.
Offerte voor Filters
Stuur norm, drukklasse en maat voor een offerteklare aanvraag — beantwoord met documenten en voorwaarden.