Vannes industrielles aux normes API · ASME · DIN · EN

Filtres

Dispositifs de filtration en ligne protégeant pompes, vannes et instruments de la contamination solide.

Dernière mise à jour : 2026-11

Caractéristiques de la famille

Designs Y-Type, Simplex Basket, Duplex Basket
Nominal valve connection size DN25 to DN500
Pressure class / nominal rating designation ANSI Class 150 to Class 300
Materials (component scope as published) WCB (ASTM A216), LCB, LCC (ASTM A352), F11, F22 (ASTM A182), CF8, CF8M (ASTM A351), F316, F316L (ASTM A182), F51/2205 duplex (ASTM A182), F53, F55/2507 super duplex (ASTM A182), C95400, C95800 aluminium bronze (ASTM B148), nickel-chromium alloy 625, nickel-copper alloy 400, nickel-molybdenum alloy C276 (ASTM B564)
Service temperature range 0 to 200°C (ductile iron Y-type strainer, water/steam/gas media)
Particle retention range The common strainer particle-retention range runs from 1 inch down to 40 micron (0.0016 inch), set by the choice of perforated metal, mesh or wedge-wire straining element.
Operation Modes Continuous flow during element cleaning (duplex basket), Shutdown required for cleaning (Y-type, simplex basket)
Basket Construction The basket or screen is the heart of the strainer; baskets are offered in stainless steel, nickel-copper alloy or brass across a wide range of perforations and mesh, removing solids from 1/2 inch and larger down to 40 microns.
Inspection and pressure-test standards API 598
design focus Structural strength under line pressure, open area and flow distribution, differential pressure behaviour, ease of maintenance and element replacement
document basis Selection, installation and maintenance guidance follows the FCI Engineering Specification for the Selection, Installation and Maintenance of Pipeline Strainers (Fluid Controls Institute, Pipeline Strainer Section, 2021).
vertical installation On vertical piping a Y strainer must be installed with its screen pointing downward so sediment is trapped in the debris collection chamber; install the strainer with the debris chamber at the lowest possible position.
duplex purpose Duplex/twin basket strainers exist for lines that cannot be shut down for basket cleanout: flow switches to the second basket while the first is removed, cleaned and replaced.
maintenance practice Schedule cleaning from the established clogging rate: pressure gauges on each side of the strainer show when cleaning is required, and differential pressure switches can drive warning lights or alarms.
Source 1 — npt pressure temperature ratings 250 PSIG @ 406°F - Steam, 400 PSIG @ 150°F - WOG
Source 1 — flanged pressure temperature ratings 125# FLG 125 PSIG @ 450°F - Steam, 125# FLG 200 PSIG @ 150°F - WOG, 250# FLG 250 PSIG @ 450°F - Steam, 250# FLG 500 PSIG @ 150°F - WOG
Source 1 — screen seat fit Machined seat assures perfect fit for screen
Source 1 — screen maintenance features Blowdown connection and easily removable stainless steel cylindrical screens for easy maintenance
Source 1 — body construction Durable cast iron body
Source 1 — wog rating definition WOG = Water, Oil or Gas
Source 1 — installation orientation installed in the flow direction as indicated on the body in either a vertical down or horizontal pipeline
Source 1 — maintenance access The strainer must be accessible for periodic cleaning.
Source 2 — body construction Flanged cast iron strainer
Source 2 — port design Pre-drilled ports
Source 2 — service media works for steam, air, water, oil and gas lines
Source 2 — system fit Ideal for lower capacity piping systems
Source 2 — cover cleaning design blow-off bottom cover for easy cleaning without removing the screen
Source 2 — screen design self-aligning cylindrical screens
Source 2 — standard screen material Stainless steel screen is standard
Source 2 — material screen options body castings and strainer screens are available in a variety of materials, perforations and mesh linings
Source 2 — steam rating Use for steam applications up to 125 psi at 350°F.
Source 2 — wog rating Use for water, oil and gas applications up to 175 psi at 150°F.
Source 3 — applicable fluids Steam, Air, Water
Source 3 — Valve body material Stainless Steel, Cast Iron, Ductile Cast Iron
Source 3 — connection types Screwed, Flanged
Source 3 — y3 model envelope Y3 Stainless Steel Screwed 15 - 50 2.1 220 60
Source 3 — yf model envelope YF Cast Iron Flanged 15 - 350 0.98 200 40
Source 3 — ydf model envelope YDF Ductile Cast Iron Flanged 15 - 250 0.98** 40
Source 3 — double layer screen Double-layer stainless steel screen with large surface area ensures trouble-free operation
Source 3 — inline cleaning design Designed for easy inline cleaning and maintenance
Source 3 — y3 all stainless design Model Y3 made entirely of stainless steel

Commande et documentation

Documents

Demandez le jeu de documentation nécessaire avec la demande — les postes types pour cette exécution (certificats matière, rapports d'essai selon la norme d'inspection indiquée, plans dimensionnels) sont confirmés et fournis avec le devis.

Devis

Une demande prête pour le devis énonce : dimension nominale et classe de pression, préférence de matériaux du corps et du siège, raccordement, commande, et le fluide avec sa température. Les valeurs typiques de cette page sont des plages de référence ; les valeurs contractuelles sont confirmées au moment du devis.

Échantillon et fourniture

Les conditions de fourniture, quantités commandées et délais sont convenus par commande — indiquez le pays de destination et le calendrier requis avec la demande.

Stockage et expédition

Stocker les vannes avec sièges et joints protégés des UV, de l'ozone et de la déformation, conserver les protections de faces d'accouplement jusqu'au montage, et pour les exécutions à siège élastomère ou PTFE éviter le stockage extérieur prolongé — les composés de siège vieillissent plus vite en plein soleil et au gel.

Questions fréquentes

Que doit inclure une demande de devis pour filtres ?

La norme et la classe de référence, la taille nominale, les matériaux de corps et de siège, le fluide de service avec sa température, et la destination — tout élément manquant est confirmé pendant le devis.

Quels taille et classe de pression sont disponibles sur filtres ?

Une plage de taille et classe de pression vérifiée pour cette vanne n'est pas encore publiée sur cette page — le taille et classe de pression applicable à votre fonction est proposé et confirmé pendant le devis. Envoyez les conditions de service avec la demande et la sélection sera énoncée dans l'offre.

Quels matériau de corps sont disponibles sur filtres ?

Une plage de matériau de corps vérifiée pour cette vanne n'est pas encore publiée sur cette page — le matériau de corps applicable à votre fonction est proposé et confirmé pendant le devis. Envoyez les conditions de service avec la demande et la sélection sera énoncée dans l'offre.

Demander un devis pour Filtres

Soumettez le besoin ici — une demande prête pour le devis énonce la norme et la classe de référence, la dimension, les matériaux, le fluide, la température et la destination.

Le traitement de vos données est décrit dans notre déclaration de confidentialité.

Obtenir un devis pour Filtres

Envoyez la norme, la classe de pression et la dimension pour une demande prête pour le devis — réponse avec documents et conditions.