Valvole industriali secondo le norme API · ASME · DIN · EN

Filtri

Dispositivi di filtrazione in linea che proteggono pompe, valvole e strumenti dalla contaminazione solida.

Ultimo aggiornamento: 2026-11

Specifiche della famiglia

Designs Y-Type, Simplex Basket, Duplex Basket
Nominal valve connection size DN25 to DN500
Pressure class / nominal rating designation ANSI Class 150 to Class 300
Materials (component scope as published) WCB (ASTM A216), LCB, LCC (ASTM A352), F11, F22 (ASTM A182), CF8, CF8M (ASTM A351), F316, F316L (ASTM A182), F51/2205 duplex (ASTM A182), F53, F55/2507 super duplex (ASTM A182), C95400, C95800 aluminium bronze (ASTM B148), nickel-chromium alloy 625, nickel-copper alloy 400, nickel-molybdenum alloy C276 (ASTM B564)
Service temperature range 0 to 200°C (ductile iron Y-type strainer, water/steam/gas media)
Particle retention range The common strainer particle-retention range runs from 1 inch down to 40 micron (0.0016 inch), set by the choice of perforated metal, mesh or wedge-wire straining element.
Operation Modes Continuous flow during element cleaning (duplex basket), Shutdown required for cleaning (Y-type, simplex basket)
Basket Construction The basket or screen is the heart of the strainer; baskets are offered in stainless steel, nickel-copper alloy or brass across a wide range of perforations and mesh, removing solids from 1/2 inch and larger down to 40 microns.
Inspection and pressure-test standards API 598
design focus Structural strength under line pressure, open area and flow distribution, differential pressure behaviour, ease of maintenance and element replacement
document basis Selection, installation and maintenance guidance follows the FCI Engineering Specification for the Selection, Installation and Maintenance of Pipeline Strainers (Fluid Controls Institute, Pipeline Strainer Section, 2021).
vertical installation On vertical piping a Y strainer must be installed with its screen pointing downward so sediment is trapped in the debris collection chamber; install the strainer with the debris chamber at the lowest possible position.
duplex purpose Duplex/twin basket strainers exist for lines that cannot be shut down for basket cleanout: flow switches to the second basket while the first is removed, cleaned and replaced.
maintenance practice Schedule cleaning from the established clogging rate: pressure gauges on each side of the strainer show when cleaning is required, and differential pressure switches can drive warning lights or alarms.
Source 1 — npt pressure temperature ratings 250 PSIG @ 406°F - Steam, 400 PSIG @ 150°F - WOG
Source 1 — flanged pressure temperature ratings 125# FLG 125 PSIG @ 450°F - Steam, 125# FLG 200 PSIG @ 150°F - WOG, 250# FLG 250 PSIG @ 450°F - Steam, 250# FLG 500 PSIG @ 150°F - WOG
Source 1 — screen seat fit Machined seat assures perfect fit for screen
Source 1 — screen maintenance features Blowdown connection and easily removable stainless steel cylindrical screens for easy maintenance
Source 1 — body construction Durable cast iron body
Source 1 — wog rating definition WOG = Water, Oil or Gas
Source 1 — installation orientation installed in the flow direction as indicated on the body in either a vertical down or horizontal pipeline
Source 1 — maintenance access The strainer must be accessible for periodic cleaning.
Source 2 — body construction Flanged cast iron strainer
Source 2 — port design Pre-drilled ports
Source 2 — service media works for steam, air, water, oil and gas lines
Source 2 — system fit Ideal for lower capacity piping systems
Source 2 — cover cleaning design blow-off bottom cover for easy cleaning without removing the screen
Source 2 — screen design self-aligning cylindrical screens
Source 2 — standard screen material Stainless steel screen is standard
Source 2 — material screen options body castings and strainer screens are available in a variety of materials, perforations and mesh linings
Source 2 — steam rating Use for steam applications up to 125 psi at 350°F.
Source 2 — wog rating Use for water, oil and gas applications up to 175 psi at 150°F.
Source 3 — applicable fluids Steam, Air, Water
Source 3 — Valve body material Stainless Steel, Cast Iron, Ductile Cast Iron
Source 3 — connection types Screwed, Flanged
Source 3 — y3 model envelope Y3 Stainless Steel Screwed 15 - 50 2.1 220 60
Source 3 — yf model envelope YF Cast Iron Flanged 15 - 350 0.98 200 40
Source 3 — ydf model envelope YDF Ductile Cast Iron Flanged 15 - 250 0.98** 40
Source 3 — double layer screen Double-layer stainless steel screen with large surface area ensures trouble-free operation
Source 3 — inline cleaning design Designed for easy inline cleaning and maintenance
Source 3 — y3 all stainless design Model Y3 made entirely of stainless steel

Ordinazione e documentazione

Documenti

Chiedi con la richiesta il pacchetto di documentazione che ti serve — gli elementi tipici per questa esecuzione (certificati dei materiali, rapporti di prova secondo la norma di ispezione indicata, disegni dimensionali) vengono confermati e forniti con il preventivo.

Preventivo

Una richiesta pronta per il preventivo indica: dimensione nominale e classe di pressione, preferenza di materiali del corpo e della sede, collegamento finale, azionamento, e il fluido di servizio con la sua temperatura. I valori tipici di questa pagina sono gamme di riferimento; i valori vincolanti vengono confermati in fase di preventivo.

Campione e fornitura

Condizioni di fornitura, quantità ordinate e tempi di consegna sono concordati per ordinativo — indica il paese di destinazione e il calendario richiesto con la richiesta.

Stoccaggio e spedizione

Conserva le valvole con sedi e tenute protette da UV, ozono e deformazione, mantieni le protezioni delle facce di tenuta fino all'installazione e, per le esecuzioni con sede in elastomero o PTFE, evita lo stoccaggio prolungato all'aperto — i composti delle sedi invecchiano più rapidamente al sole diretto e al gelo.

Domande frequenti

Cosa deve includere una richiesta di preventivo per filtri?

La norma e la classe applicabili, la dimensione nominale, i materiali di corpo e seduta, il fluido di servizio con la temperatura e la destinazione — ciò che manca è confermato durante il preventivo.

Quali dimensione e classe di pressione sono disponibili in filtri?

Un intervallo verificato di dimensione e classe di pressione per questa valvola non è ancora pubblicato su questa pagina — il dimensione e classe di pressione applicabile al vostro servizio è proposto e confermato in fase di preventivo. Inviate le condizioni di servizio con la richiesta e la selezione è indicata nell'offerta.

Quali materiale del corpo sono disponibili in filtri?

Un intervallo verificato di materiale del corpo per questa valvola non è ancora pubblicato su questa pagina — il materiale del corpo applicabile al vostro servizio è proposto e confermato in fase di preventivo. Inviate le condizioni di servizio con la richiesta e la selezione è indicata nell'offerta.

Richiedi un preventivo per Filtri

Invia qui l'esigenza — una richiesta pronta per il preventivo indica la norma e la classe di riferimento, la dimensione, i materiali, il fluido, la temperatura e la destinazione.

Cosa accade ai tuoi dati è descritto nell'informativa sulla privacy.

Ottieni un preventivo per Filtri

Invia norma, classe di pressione e dimensione per una richiesta pronta per il preventivo — risposta con documenti e condizioni.