Industriearmaturen nach API · ASME · DIN · EN

Schmutzfänger

Inline-Filtereinrichtungen, die Pumpen, Ventile und Instrumente vor Feststoffkontamination schützen.

Zuletzt aktualisiert: 2026-11

Familienspezifikationen

Designs Y-Type, Simplex Basket, Duplex Basket
Nominal valve connection size DN25 to DN500
Pressure class / nominal rating designation ANSI Class 150 to Class 300
Materials (component scope as published) WCB (ASTM A216), LCB, LCC (ASTM A352), F11, F22 (ASTM A182), CF8, CF8M (ASTM A351), F316, F316L (ASTM A182), F51/2205 duplex (ASTM A182), F53, F55/2507 super duplex (ASTM A182), C95400, C95800 aluminium bronze (ASTM B148), nickel-chromium alloy 625, nickel-copper alloy 400, nickel-molybdenum alloy C276 (ASTM B564)
Service temperature range 0 to 200°C (ductile iron Y-type strainer, water/steam/gas media)
Particle retention range The common strainer particle-retention range runs from 1 inch down to 40 micron (0.0016 inch), set by the choice of perforated metal, mesh or wedge-wire straining element.
Operation Modes Continuous flow during element cleaning (duplex basket), Shutdown required for cleaning (Y-type, simplex basket)
Basket Construction The basket or screen is the heart of the strainer; baskets are offered in stainless steel, nickel-copper alloy or brass across a wide range of perforations and mesh, removing solids from 1/2 inch and larger down to 40 microns.
Inspection and pressure-test standards API 598
design focus Structural strength under line pressure, open area and flow distribution, differential pressure behaviour, ease of maintenance and element replacement
document basis Selection, installation and maintenance guidance follows the FCI Engineering Specification for the Selection, Installation and Maintenance of Pipeline Strainers (Fluid Controls Institute, Pipeline Strainer Section, 2021).
vertical installation On vertical piping a Y strainer must be installed with its screen pointing downward so sediment is trapped in the debris collection chamber; install the strainer with the debris chamber at the lowest possible position.
duplex purpose Duplex/twin basket strainers exist for lines that cannot be shut down for basket cleanout: flow switches to the second basket while the first is removed, cleaned and replaced.
maintenance practice Schedule cleaning from the established clogging rate: pressure gauges on each side of the strainer show when cleaning is required, and differential pressure switches can drive warning lights or alarms.
Source 1 — npt pressure temperature ratings 250 PSIG @ 406°F - Steam, 400 PSIG @ 150°F - WOG
Source 1 — flanged pressure temperature ratings 125# FLG 125 PSIG @ 450°F - Steam, 125# FLG 200 PSIG @ 150°F - WOG, 250# FLG 250 PSIG @ 450°F - Steam, 250# FLG 500 PSIG @ 150°F - WOG
Source 1 — screen seat fit Machined seat assures perfect fit for screen
Source 1 — screen maintenance features Blowdown connection and easily removable stainless steel cylindrical screens for easy maintenance
Source 1 — body construction Durable cast iron body
Source 1 — wog rating definition WOG = Water, Oil or Gas
Source 1 — installation orientation installed in the flow direction as indicated on the body in either a vertical down or horizontal pipeline
Source 1 — maintenance access The strainer must be accessible for periodic cleaning.
Source 2 — body construction Flanged cast iron strainer
Source 2 — port design Pre-drilled ports
Source 2 — service media works for steam, air, water, oil and gas lines
Source 2 — system fit Ideal for lower capacity piping systems
Source 2 — cover cleaning design blow-off bottom cover for easy cleaning without removing the screen
Source 2 — screen design self-aligning cylindrical screens
Source 2 — standard screen material Stainless steel screen is standard
Source 2 — material screen options body castings and strainer screens are available in a variety of materials, perforations and mesh linings
Source 2 — steam rating Use for steam applications up to 125 psi at 350°F.
Source 2 — wog rating Use for water, oil and gas applications up to 175 psi at 150°F.
Source 3 — applicable fluids Steam, Air, Water
Source 3 — Valve body material Stainless Steel, Cast Iron, Ductile Cast Iron
Source 3 — connection types Screwed, Flanged
Source 3 — y3 model envelope Y3 Stainless Steel Screwed 15 - 50 2.1 220 60
Source 3 — yf model envelope YF Cast Iron Flanged 15 - 350 0.98 200 40
Source 3 — ydf model envelope YDF Ductile Cast Iron Flanged 15 - 250 0.98** 40
Source 3 — double layer screen Double-layer stainless steel screen with large surface area ensures trouble-free operation
Source 3 — inline cleaning design Designed for easy inline cleaning and maintenance
Source 3 — y3 all stainless design Model Y3 made entirely of stainless steel

Bestellung & Dokumentation

Unterlagen

Fordern Sie den benötigten Unterlagensatz mit der Anfrage an — übliche Positionen für diese Ausführung (Werkstoffzeugnisse, Prüfberichte nach der genannten Prüfnorm, Maßzeichnungen) werden bestätigt und mit dem Angebot geliefert.

Angebot

Eine angebotsreife Anfrage nennt: Nenngröße und Druckstufe, bevorzugten Gehäuse- und Sitzwerkstoff, Anschlussart, Betätigung sowie das Fördermedium mit Temperatur. Typische Werte auf dieser Seite sind Benchmark-Referenzbereiche; die verbindlichen Werte werden im Angebot bestätigt.

Muster & Lieferung

Lieferbedingungen, Bestellmengen und Lieferzeit werden je Bestellung vereinbart — nennen Sie das Bestimmungsland und den benötigten Termin mit der Anfrage.

Lagerung & Versand

Armaturen so lagern, dass Sitze und Dichtungen vor UV, Ozon und Verformung geschützt sind, Schutzkappen an den Dichtflächen bis zum Einbau belassen und bei Ausführungen mit Elastomer- oder PTFE-Sitz langfristige Freilagerung vermeiden — Sitzwerkstoffe altern am schnellsten unter direkter Sonne und bei Frost.

Häufig gestellte Fragen

Was sollte eine Angebotsanfrage für schmutzfänger enthalten?

Die maßgebliche Norm und Klasse, Nennweite, Gehäuse- und Sitzwerkstoffe, das Betriebsmedium mit Temperatur sowie das Bestimmungsziel — alles Fehlende wird während der Angebotserstellung geklärt.

Welche Größe und Druckstufe sind für schmutzfänger verfügbar?

Ein verifizierter Bereich für Größe und Druckstufe ist für diese Armatur auf dieser Seite noch nicht veröffentlicht — der für Ihre Aufgabe zutreffende Größe und Druckstufe wird im Angebot vorgeschlagen und bestätigt. Senden Sie die Betriebsbedingungen mit der Anfrage, und die Auswahl wird im Angebot genannt.

Welche Gehäusewerkstoff sind für schmutzfänger verfügbar?

Ein verifizierter Bereich für Gehäusewerkstoff ist für diese Armatur auf dieser Seite noch nicht veröffentlicht — der für Ihre Aufgabe zutreffende Gehäusewerkstoff wird im Angebot vorgeschlagen und bestätigt. Senden Sie die Betriebsbedingungen mit der Anfrage, und die Auswahl wird im Angebot genannt.

Angebot für Schmutzfänger anfordern

Senden Sie die Anforderung hier — eine angebotsreife Anfrage nennt maßgebliche Norm und Druckstufe, Größe, Werkstoffe, Medium, Temperatur und Bestimmungsland.

Was mit Ihren Angaben geschieht, ist in unserer Datenschutzerklärung beschrieben.

Angebot für Schmutzfänger erhalten

Senden Sie Norm, Druckstufe und Größe für eine angebotsreife Anfrage — beantwortet mit Unterlagen und Bedingungen.