API · ASME · DIN · EN 標準工業閥門

同心蝶閥

同心蝶閥保持閥桿居中於蝶盤、蝶盤居中於流道,橡膠密封蝶盤全周均勻受力——低壓公用與一般工業用途中經濟輕量的 1/4 迴轉選擇。產品範圍涵蓋 2" 至 72"(DN 50 至 DN 1800),PN6-PN16(85-232 psi),閥體為球墨鑄鐵、碳鋼、不鏽鋼或青銅,端接有對夾、凸耳與 RF 法蘭,操作為手柄、蝸輪、氣動、電動或液動。密封基於彈性體——EPDM(飲用水 WRAS)、NBR(油類服務)或 PTFE(pH 1-14 腐蝕介質)——引用軟密封結構具 EN 12266 Class A 零洩漏關斷,鳩尾/壓環式閥座可在線更換。由於蝶盤在部分行程中摩擦閥座,閥座摩擦、扭矩(約 90 度行程,引用結構 DN200 手動 ≤80 N-m)、溫度(典型 -20 至 120 C,升級 304L 可至 -40 C)與介質相容性決定使用界限;更高溫度或壓力應轉用單偏心與多偏心設計。標準涵蓋 API 609、MSS SP-67、ISO 17292、GB/T 12238 與 EN 593,並提供 API 598 水壓驗收與 API 607 防火認證。

屬於 蝶閥 系列

最後更新: 2026-11

系列規格

Nominal valve connection size 2”~72”(DN50-DN1800)
Pressure class / nominal rating designation 85~232Psi(PN6~PN16)
Seat material NBR, EPDM, PTFE
Disc Materials Ductile Iron, SS304, SS316
Stem material Stainless Steel 420, Stainless Steel 410
Valve body material Ductile Iron, Carbon Steel, Stainless Steel, Copper
End connection types Wafer, Lug, RF
Operation / closure mode Lever, Gear, Pneumatic, Electric, Hydraulic
Seat leakage class Seat leakage on the referenced line is specified at EN 12266 Class A with a leakage rate of 5x10-8 m3/s or less, i.e. zero-leakage soft-seal shutoff.
Service temperature range 0 to 80 C
Design standards API 609
Design standards DIN 3202, DIN 2501 PN10/PN16
Face-to-face dimensional standard BS 5155
zero offset definition Definition: a concentric butterfly valve is a quarter-turn valve in which the shaft, disc centre and body centreline are aligned in a zero-offset arrangement, so the disc edge compresses a resilient seat to seal.
sealing principle Sealing is elastomer-based: soft seat materials such as EPDM, NBR or PTFE let the disc press firmly into the seat for a leak-proof seal without excessive torque.
seat temp pressure limits Elastic seats set the operating ceiling: high-temperature or abrasive media compromise the seat, which is why the type is generally kept to moderate conditions.
seat friction torque Because the disc rubs against the resilient seat through part of its travel, seat friction, operating torque, temperature limits and media compatibility must be checked at selection rather than assumed.
standards frame Applicable standards span API 609 (wafer/lug/double-flanged), MSS SP-67, ISO 17292 for petroleum service and GB/T 12238 for flanged and wafer connection valves; EN 593 is cited as the European counterpart.
standards project dependent The exact standard and edition are product- and project-dependent; buyers should specify API 609 or EN 593 plus the required inspection and leakage test requirements.
size envelope oem A representative OEM concentric soft-seal line covers DN40-DN1200 as standard with DN1400-DN2000 available only after engineering evaluation - well inside the tenant band of DN50-DN1800.
pressure envelope oem Standard pressure ratings are PN10/PN16 (1.0/1.6 MPa) with a PN25 (2.5 MPa) upgrade path on the referenced execution.
temperature envelope The referenced soft-seal execution serves water, air and oil media from -20 C to 120 C; a low-temperature tested variant to -40 C requires a 304L material upgrade.
low temp option Cryogenic-leaning duties are handled by option rather than standard build: the referenced line lists low-temperature testing to -40 C with material upgraded to 304L.
seat material specifics Seat media matching: EPDM for drinking water (WRAS certified), NBR for oil media (ASTM No. 3 oil test) and PTFE for strongly corrosive service across pH 1-14.
seat replaceability The seat is retained by a dovetail groove or pressure ring so it can be replaced online without removing the valve from the line after wear.
lug end function The lug body carries threaded inserts both sides, letting the valve be installed independent of the downstream flange so pipework can be opened for maintenance without draining the system.
connection classification Connection variants beyond wafer/lug include double-flange bodies for higher pressure or larger diameter and butt-weld bodies welded permanently into petrochemical lines.
open flow resistance Even fully open the disc and shaft remain in the flow passage, so some pressure loss persists and scales with diameter and disc/shaft geometry.
eccentric development The single-eccentric (offset) design exists specifically to answer concentric wear: offsetting the stem from the disc centre reduces friction, extends sealing life and opens the door to higher temperature and pressure duties.
actuation torque Manual builds use a fixed 90-degree stroke with limit-stop feedback; on the referenced line lever operation needs no more than 80 N-m at DN200.
testing frame Acceptance testing on the referenced line runs to API 598 hydrostatic at 1.5 times rating, with API 607 fire-safe certification available through a metal-seal redundancy design.
seat temperature ratings table Buna-N seat: +10 to 180 °F (-12 to 82 °C), EPDM seat (2"–16"): -30 to 275 °F (-34 to 135 °C), EPDM seat (18" and above): -30 to 225 °F (-34 to 107 °C), fluoroelastomer (FKM) seat: 10 to 400 °F (-12 to 204 °C)
tight shutoff pressure rating pressure ratings for tight shutoff up to the seat material temperature limit on wafer and lug bodies: 200 psi for 2"–12" and 150 psi for 14"–72"
double flange tight shutoff pressure rating pressure ratings for tight shutoff up to the seat material temperature limit on double-flanged bodies: 232 psi for 3"–14" and 150 psi for 16"–72"
cv fullopen wafer lug full-open Cv (US-GPM at 1 psi ΔP) spans 115 at 2 in to 73,426 at 30 in on wafer and lug style bodies
cv partial open 70deg Cv at 70° disc opening spans 70 at 2 in to 44,545 at 30 in (US-GPM at 1 psi ΔP)
cv partial open 50deg Cv at 50° disc opening spans 27 at 2 in to 17,010 at 30 in (US-GPM at 1 psi ΔP)
torque test basis sizing seating/unseating torque charts derived from test data with water at 60°F; dry-gas duties multiply by 2.0; figures carry no safety factor — multiply by 1.2 for single-valve actuator sizing or 2.0 for three-way (tee) applications
vacuum service rating vacuum service rating: zero leakage at 24 in Hg vacuum
dead end pressure rating bi-directional dead-end service capability to 200 psi (2"–12") and 150 psi (14"–24") is standard on lug style valves
asme flange compatibility compatible with ASME B16.1 and ASME B16.5 flanges (2"–24"), compatible with ASME B16.47 Series A (MSS SP-44) flanges (28"–72")
mss design compliance designed to comply with MSS SP-67 and MSS SP-25
awwa proof of design valves 2"–20" meet the intent of and have passed the AWWA C504-87 Section 5 proof of design tests
potable water ped certification CE/PED certification available for 2"–24", NSF/ANSI 61 & 372 certified for potable water and lead-free service (aluminium-bronze or stainless steel builds)
marine type approval type approval certification from ABS and USCG Category A for marine applications (2"–24")
seat temperature service caveats at low temperature the elastomer durometer changes — the hardened seat may increase operating torque beyond the structural limits of the stem and/or disc-to-stem configuration, published temperature ranges may have to be modified in valve duty; ranges shown are adjusted accordingly, on the fluoroelastomer (FKM) seat build the operating pressure is reduced above 275°F, field replacement of seats in sizes 14" and above requires factory service
composite execution envelope composite-body resilient seated wafer line: DN 40 to 300 (NPS 1.5 to 12), -40 to +150 °C (-40 to +300 °F), 10/16 bar (145/232 psi), flange drilling DIN PN 6/10/16, ASME 150, JIS 10K and AS 2129 Table E
face to face resilient composite face-to-face per EN 558-1/Table 5 and API 609
iso5211 integrated top plate integrated ISO 5211 top plate: actuator flange per ISO 5211 without a separate mounting bracket
line velocity limit usable in high line velocity applications up to 12 m/sec
bidirectional leak rate bubble-tight shut-off in both directions per EN 12266-1 leak rate A
water marine approvals water approvals KIWA, WRAS and NSF; certified and approved per Det Norske Veritas (DNV)
iso5211 pad series by size ISO 5211 pad series F-05 (DN40–DN50), F-07 (DN65–DN150) and F-12 (DN200–DN300)
shaft diameter envelope shaft diameter (h9 class) 12 mm at DN40–DN50 up to 25 mm at DN250–DN300
stem seal dual design primary stem sealing exceeds the valve pressure rating and prevents shaft-area leakage to atmosphere; a secondary shaft sealing provides back-up safety
kv fullopen largest size highest tabulated Kv/Cv value is 9,872.0 / 11,452.00 at the largest listed size fully open (90° column)
composite weight envelope valve mass 0.6 kg (DN40) rising to 10.8 kg (DN300) on the composite execution
face to face din series face-to-face EN 558 Series 20, face-to-face ISO 5752 Series 20, face-to-face API 609 Table 1
flange accommodation standards flange drilling EN 1092 PN 6/10/16, ASME Class 150, AS 4087 PN 16, flange face EN 1092 Form A/B, ASME RF/FF
top flange iso5211 marking top flange per EN ISO 5211; valve marking per EN 19
tightness dual standard tightness check per EN 12266 leakage rate A and ISO 5208 Category 3
extended temp pressure envelope a resilient wafer execution rated -40°C to +200°C (depending on pressure, medium and material) at a maximum operating pressure of 16 bar
kv test basis throttling Kv is the water flow in m³/h at 5°C to 30°C (41°F to 86°F) at 1 bar ΔP; published Kv values based on tests by the Delft Hydraulics Laboratories (Netherlands); throttle function linear between 30° and 70° opening
flow velocity limits permissible flow velocity max. 4.5 m/s for liquids and max. 70 m/s for gases
breakaway torque basis published torque values are initial breakaway torques taken with liquids and lubricating media, to be treated as approximate: the effective value depends on pressure, medium, rubber quality and temperature
shaft guidance design triple shaft bearings prevent shaft deflection and guarantee valve guidance over long service; four flange mounting holes locate the valve between flanges; installation in any desired position; maintenance-free
seat material code options seat material options NBR, EPDM, CSM, FPM and VSI
shaft material options shaft material options stainless steels X39CrMo17-1 and X14CrMoS17, or nickel-molybdenum alloy
size 2”~72”(DN50-DN1800)
Pressure Rating 85~232Psi(PN6~PN16)
end connection Wafer, Lug, RF
medium Water, Oil, Gas
top flange ISO 5211

範圍與來源備註

size envelope Size envelope: tenant band DN50-DN1800 (2in-72in) exceeds the referenced Tianyu standard range DN40-DN1200, which only reaches DN1400-DN2000 after engineering evaluation - the tenant band is an aggregate of OEM envelopes, not one build.
pressure framing Pressure framing: tenant reference 85-232 psi (PN6-PN16) matches the standard PN10/16 builds, but the Tianyu line offers a PN25 (2.5 MPa) upgrade path that sits outside the tenant reference range.
standard coverage Standard coverage: existing design_standard lists API 609 only, while industry practice spans API 609, MSS SP-67, ISO 17292, GB/T 12238 and EN 593 - edition and scope are project-dependent.
leakage claim Leakage claim: EN 12266 Class A zero-leakage soft-seal shutoff is a referenced-OEM figure; hard-seated or high-temperature builds will not meet the same class.

訂購與文件

文件

請在詢問時一併說明您需要的文件組合——此結構的常見項目(材質證明、按所列檢驗標準的測試報告、尺寸圖)將於報價時確認並隨附供應。

報價

可直接報價的詢問應說明:公稱口徑與壓力額定、閥體與閥座材質偏好、端部連接、操作方式,以及含溫度的使用介質。本頁的典型值為基準參考範圍;具有約束力的數值於報價時確認。

樣品與供應

供應條件、訂購數量與交期按訂單議定——請在詢問時說明目的地國家與所需時程。

儲存與運輸

閥門儲存時應保護閥座與密封件免受紫外線、臭氧與變形影響,安裝前保留端面保護蓋;彈性體或 PTFE 閥座結構應避免長期戶外存放——閥座材料在陽光直射與冰凍條件下老化最快。

常見問題

同心蝶閥的報價詢問應包含哪些內容?

執行標準與壓力等級、公稱口徑、閥體與閥座材質、介質及溫度、目的地——缺失的資訊會在報價過程中確認。

同心蝶閥提供哪些口徑與壓力等級?

本頁面尚未公布該閥門經驗證的口徑與壓力等級範圍——適用於您工況的口徑與壓力等級會在報價過程中提出並確認。請在詢問時附上工況條件,選型結果會在報價中說明。

同心蝶閥提供哪些閥體材質?

本頁面尚未公布該閥門經驗證的閥體材質範圍——適用於您工況的閥體材質會在報價過程中提出並確認。請在詢問時附上工況條件,選型結果會在報價中說明。

請求同心蝶閥報價

在此提交需求——可直接報價的詢問應說明適用標準與等級、口徑、材質、介質、溫度與目的地.

您的資料如何處理,詳見我們的隱私權公告。

取得同心蝶閥報價

提供標準、壓力等級與口徑,即可形成可直接報價的詢問——我們將附文件與條件回覆。