패밀리 사양
| Nominal valve connection size | DN20 to DN400 |
|---|---|
| Pressure class / nominal rating designation | PN16 to PN64, ANSI Class 150 to Class 2500 |
| Service temperature range | -10 to 70°C (direct-acting, water), 0 to 80°C (200X, water) |
| End connection types | Flanged (EN 1092) |
| Design standards | ASME B16.34 |
| Inspection and pressure-test standards | API 598 |
| Designs | Direct Acting, Steam, Water, Pilot Operated, Pressure Relief and Sustaining, Float Control |
| Materials (component scope as published) | WCB (ASTM A216), CF8, CF8M (ASTM A351), F316, F316L (ASTM A182), F51/2205 duplex (ASTM A182), F11, F22 (ASTM A182), GG25 cast iron (EN 1561), GGG40, GGG50 ductile iron (EN 1563), C95400, C95800 aluminium bronze (ASTM B148), C83600, LG2 bronze (ASTM B62), CW617N, DZR brass (EN 12165) |
| accuracy behaviour | For pilot-operated steam regulators, set pressure is more stable and varies only a few percent over the full flow range. |
| internals material example | Benchmark pilot-operated steam regulators use all stainless steel internals for high-pressure applications up to 450 PSIG. |
| seat hardness example | Hardened stainless steel seat and disc (55 Rc). |
| size capacity example | Benchmark pilot-operated steam segment: sizes 1/2" to 4", NPT or 150/300 flanged connections, PMO 20 to 450 PSIG, steam capacity to 83,300 lbs/hr. |
| operating principle | A pilot-operated regulator uses a pilot (a small regulator) that senses the outlet pressure and controls the main valve through a pilot line, modulating the pressure on one side of the main valve actuator so the valve opens or closes to maintain the set pressure. |
| selection guidance | Direct-acting regulators suit small-scale applications for their simplicity and cost; pilot-operated regulators serve harsh industrial environments where high flow rates are required. |
| droop definition | Pressure droop is the reduction in the controlled outlet pressure of a pressure reducing regulator as the flow rate increases — an intrinsic characteristic of the internal force-balance mechanism, not a malfunction. Because the regulator is proportional-only in control, the outlet pressure must decrease slightly to re-establish force balance as flow rises; the setpoint is defined at a very low flow rate, just outside the lockup zone. |
| droop mitigation | Droop is reduced by a larger body size with higher Cv capacity, flexible composition diaphragm material, the largest available port size, softer and longer range springs, or pressure-loaded (dome-loaded) designs; pilot-operated regulators with integral "reset" action eliminate steady-state droop altogether. |
| droop typical value example | Benchmark dome-loaded regulator capacity tables are based on 95% accuracy (2 psi minimum droop). |
| pilot setpoint accuracy | Pilot-operated steam regulators hold secondary set pressure within ±0.01 MPa, maintained even when steam load or primary pressure at the valve changes. |
| pilot steam line envelope | Pilot-operated steam line example envelope: PMO 250 psig, TMO 428°F, primary pressure 30-250 psig, secondary pressure 5-210 psig, max flow capacity 47,380 lb/h, cast iron (FC250) body. |
| pilot droop quantified | Pilot-operated regulators: the fall in downstream pressure from fully open to fully closed is typically less than three hundredths of a bar (3 kPa; 0.5 psi). |
| pilot capacity vs direct | A pilot-operated pressure reducing valve will usually be smaller than a direct acting valve of the same capacity. |
| hydronic prv body materials | Hydraulic pilot-operated PRV body and cover material options: ductile iron, cast steel, or bronze. |
| hydronic prv trim materials | Trim (disc guide, seat, cover bearing): bronze standard, stainless steel optional. |
| hydronic prv stem spring | Stem, nut and spring: stainless steel. |
| hydronic prv check feature | With an added check feature, a pressure reversal admits downstream pressure into the main valve cover chamber, closing the valve to prevent return flow. |
| hydronic parallel station | Wide-range reducing stations use two pilot-operated reducing valves in parallel: the larger valve meets peak loads while the smaller handles low flows; a downstream pressure relief valve is recommended for such stations. |
| pilot drip tight closure | When downstream pressure exceeds the control pilot setting, the main valve and pilot valve close drip-tight. |
| anti cavitation trim | Anti-cavitation trim variants exist for high-differential duty: they provide optimum downstream pressure control while reducing cavitation noise and damage, and candidacy is screened with a cavitation guide/chart. |
주문·서류
서류
문의 시 필요한 서류 세트를 요청해 주십시오 — 이 구조의 일반적인 항목(재질증명서, 명시된 검사 표준에 따른 시험 성적서, 치수 도면)은 견적 시 확인되어 함께 공급됩니다.
견적
견적에 바로 쓸 수 있는 문의에는 다음을 명시합니다: 공칭 구경과 압력 정격, 바디·시트 재질 선호, 접속 방식, 조작 방식, 온도를 포함한 사용 유체. 이 페이지의 전형값은 벤치마크 참조 범위입니다; 구속력 있는 값은 견적 시 확정됩니다.
샘플·공급
공급 조건, 발주 수량, 납기는 주문별로 합의합니다 — 문의 시 납품 국가와 필요한 일정을 알려 주십시오.
보관·운송
밸브는 시트와 씰을 자외선, 오존, 변형으로부터 보호하여 보관하고, 설치까지 단면 보호캡을 유지하십시오; 탄성체 또는 PTFE 시트 구조는 장기 야외 보관을 피하십시오 — 시트 재료는 직사광선과 동결 조건에서 가장 빨리 노화됩니다.
자주 묻는 질문
감압 밸브 견적 문의에는 무엇을 포함해야 하나요?
적용 표준과 등급, 공칭 구경, 바디 및 시트 재질, 온도를 포함한 서비스 유체, 그리고 납품지를 알려 주십시오 — 누락된 항목은 견적 진행 중 확인됩니다.
감압 밸브에서 어떤 구경 및 압력 등급을(를) 이용할 수 있나요?
이 밸브에 대해 검증된 구경 및 압력 등급 범위는 아직 이 페이지에 공개되어 있지 않습니다 — 사용 조건에 맞는 구경 및 압력 등급은 견적 과정에서 제안 및 확인됩니다. 문의 시 서비스 조건을 함께 보내 주시면 견적서에 선정 결과를 명시해 드립니다.
감압 밸브에서 어떤 바디 재질을(를) 이용할 수 있나요?
이 밸브에 대해 검증된 바디 재질 범위는 아직 이 페이지에 공개되어 있지 않습니다 — 사용 조건에 맞는 바디 재질은 견적 과정에서 제안 및 확인됩니다. 문의 시 서비스 조건을 함께 보내 주시면 견적서에 선정 결과를 명시해 드립니다.
이 패밀리의 타입
타입
직접 작동 감압 밸브
직접 작동 감압 밸브는 하나의 컴팩트한 바디에서 하류 압력을 설정 스프링과 평형시키므로, 파일럿 라인이나 외부 감지가 필요 없습니다 — 공기, 물, 경량 공정 라인의 안정적·중간 부하에 맞는 단순한 응답입니다. 범위는 구상주철(EN-GJS-450/10) 바디 및 보닛에 스테인리스 시트,
사양 보기 →
타입
파일럿 작동 감압 밸브
파일럿 작동 감압 밸브는 작은 파일럿 밸브를 통해 하류 압력이 큰 다이어프램에 작용하도록 하여, 컴팩트한 바디가 직접 스프링 방식이 유지할 수 없는 정밀도로 고유량을 조절합니다 — 수요 변동이 큰 상수도 계통의 선택입니다. 범위는 주철 바디 및 밸브 플랩에 주철 프레스 플레이트, NBR
사양 보기 →
타입
스팀 감압 밸브
스팀 감압 밸브는 고압 헤더의 생증기 또는 포화증기를 기기, 트레이싱, 난방 스테이션이 실제 사용하는 안정적인 저압으로 강하시키며, 보일러 측이 변동하더라도 출구 압력을 일정하게 유지합니다. 범위는 구상주철 또는 WCB 바디에 2Cr13 디스크, SS410/2Cr13 시트, 플러그 및
사양 보기 →
타입
수도용 감압 밸브
수도용 감압 밸브는 급수, 소방, 배수 계통에서 고정된 하류 압력을 유지하여, 양수관 또는 부스트펌프가 공급하는 높은 상류 압력으로부터 위생 기기와 계기를 보호합니다. 범위는 주철, 주강 또는 구상주철 바디에 스테인리스 시트, 피스톤, 링, 슬리브로, DN20~DN400, PN16~PN
사양 보기 →타입
압력 방출/유지 밸브
압력 방출/유지 밸브는 상류 압력을 방어합니다: 통상 폐쇄형 파일럿이 입구 라인을 감지하여, 상류 압력이 파일럿 설정값 아래면 메인 밸브가 닫힌 채로 있고, 설정값을 넘으면 파일럿이 다이어프램 챔버를 조절해 밸브가 열려 잉여 유량을 방출하며 최소 상류(유지/배압) 수위를 지킵니다. 동일
사양 보기 →
타입
플로트 컨트롤 밸브
플로트 컨트롤 밸브는 탱크의 플로트 파일럿이 보고하는 수위로 개폐하며, 저수지와 감압조를 설정 수위까지 채우고 펌프의 단기 반복 기동 없이 차단합니다. 범위는 주철 또는 구상주철 바디, 커버, 스템, 시트에 스테인리스 스프링 및 고무 다이어프램으로, PN10/PN16/PN25 정격(공칭
사양 보기 →
타입
서지 안티시페이터 밸브
서지 안티시페이터 밸브는 파일럿 제어 다이어프램 밸브로, 압력 상승 천이에서 열려 서지가 커지기 전에 대기 또는 환류 라인으로 방출합니다 — 서서히 닫히는 체크 밸브만으로는 노출되는 장거리 양수 간선의 방어입니다. 사이즈는 PN 10/16/25/40에서 DN 50~DN 600으로, 구상
사양 보기 →감압 밸브 견적 요청
여기서 요구사항을 제출하십시오 — 견적에 바로 쓸 수 있는 문의에는 적용 표준과 등급, 구경, 재질, 유체, 온도, 납품지가 담겨 있습니다.